Sign in

NCT04119986Not yet recruiting

Safety and Efficacy of DCB Therapy for ISR Under the Guidance of QFR (UNIQUE-DCB-II Study )

Safety and Efficacy of Drug Coated Balloon Therapy for Coronary In-stent Restenosis in Patients With Coronary Heart Disease Under the Guidance of QFR (UNIQUE-DCB-II Study)

Source: ClinicalTrials.gov · Last updated 31 May 2025 · Not updated for over 12 months - ask the site whether it is still open

Brief summary (registry, in English)

In 1970, the first percutaneous balloon coronary angioplasty opened a new chapter of interventional therapy. However, the incidence of intracoronary restenosis was about 30%. Subsequently, bare metal stents and drug-eluting stents (DES) reduced the incidence of in-stent restenosis (ISR) to 5%-10% and it was still a bottleneck treated by percutaneous coronary intervention (PCI). Currently, ISR is mainly treated by balloon angioplasty, stent implantation and coronary artery bypass grafting. In 2014, the guidelines of the European Society of Cardiology recommended that drug balloon therapy (DCB) and new generation DES should be the preferred strategies for ISR treatment. Compared with DES, DCB treatment can avoid the inflammation of intima caused by multi-layer stent strut, and reduce the risk of intimal hyperplasia and thrombosis in stent. However, DCB lacks sustained radial support. Even if the residual stenosis is less than 30% after sufficient pre-dilation, the elastic retraction of the intima still exists. In addition, the antiproliferative effect of paclitaxel is significantly worse than that of sirolimus and its derivatives, and there is a lack of long-term sustained release of anti-proliferative drugs. Compared with DCB, DES can obtain long-term stable radial support and long-term anti-proliferation effect, but stent struts exposed in the vascular lumen are at risk of stent thrombosis. The new generation of DES improves the design of stent platform, improves the polymer coating, and applies new anti-proliferative drugs. It effectively reduces the inflammation of vascular wall, speeds up the process of vascular re-endothelialization, promotes early vascular repair, and significantly reduces the incidence of stent thrombosis. Recent BIOLUXRCT, RESTORE and DARE studies provide more powerful evidence for the treatment of ISR by new generation DES. Quantitative flow ratio (QFR) is the second generation FFR detectional method based on coronary contrast image. The latest FAVOR II results also confirm that QFR is more sensitive and specific than quantitative coronary analysis (QCA) in the diagnosis of myocardial ischemia caused by coronary artery stenosis. However, there is no report of ISR treated with DCB under the guidance of QFR. The aim of this study was to evaluate the safety and efficacy of DCB in the treatment of in-stent restenosis in patients with coronary heart disease (CHD) under the guidance of QFR compared with DES implantation.

Status (registry)
Not yet recruiting
Study type
Interventional
Enrollment
220 (estimated)
First submitted
7 Oct 2019
Start date
1 Jan 2026
Primary completion date
1 Dec 2028
Lead sponsor
Nanjing First Hospital, Nanjing Medical University
NCT number
NCT04119986

What you commit to

  • Study type: Interventional
  • Planned participants: 220
  • From 1 Jan 2026 to the primary completion date, 1 Dec 2028
  • 1 site in 1 country
  • Visits and tests: ask the trial team, the registry does not list them

Built from the registry fields of ClinicalTrials.gov. It describes the study design.

Who cannot take part

Copied verbatim from ClinicalTrials.gov and grouped by topic. Only the trial team decides who can take part.

Prior treatment

  • A history of peptic ulcer or GI bleeding in the previously
  • Stroke within 6 months prior to the operation

Other illness

  • QFR less than 0.8, dissection above type B and thrombosis formation after pre-dilation of ISR
  • Severe valvular heart disease
  • Known intolerance or allergy to heparin, contrast agents, paclitaxel, iopromide, rapamycin, polylactic acid-glycolic acid copolymer, Co-Cr alloy or platinum-chromium alloy
  • A history of severe hepatic or renal failure

Lab values

  • Severe congestive heart failure \[LVEF \<30% or NYHA( New York Heart Association) III/IV)\]

Other

  • Life expectancy no more than 1 year or factors causing difficulties in clinical follow up
  • Intolerance to aspirin and/or clopidogrel
  • Leukopenia or thrombopenia

Who the study is looking for

  • ● Meet the diagnostic criteria for patients with coronary in-stent restenosis and QFR\<0.8 of target lesion in the coronary stent

Age in the registry: 18 years to 100 years · Sex: All · Does not accept healthy volunteers

Full criteria on ClinicalTrials.gov

Sites (1)

Sites in registry order. Save your city in your profile to sort them by distance.

SiteCityCountrySite status
Nanjing First Hospital
Coordinator of this site? Confirm its status
NanjingChinaUnknown status

This page is information, not medical advice. Discuss any trial with your doctor.