Brief summary (registry, in English)

"This investigator-initiated, prospective, single-center clinical study evaluates the performance and clinical utility of a single-lead electrocardiogram (ECG) patch-based telemetry system for hospitalized patients who require in-hospital telemetry ECG monitoring. The system integrates real-time centralized surveillance (MEMO-Cue) with post-hoc analytic review (MEMO-Care) using ECG signals recorded by the MEMO Patch M, aiming to enable timely recognition of clinically important arrhythmias and to inform treatment decisions under routine inpatient conditions. Adults (≥19 years) indicated for continuous ECG monitoring during admission are enrolled after written informed consent, with a planned sample size of 100 to yield approximately 90 evaluable participants (10% anticipated dropout). The design does not include randomization or blinding. Study procedures include a screening visit (eligibility and baseline data), an inpatient monitoring period of at least 12 hours and up to 8 days with simultaneous MEMO-Cue monitoring and MEMO Patch M recording, and an end-of-visit assessment when MEMO-Care analytic results become available. Concomitant therapies deemed clinically necessary are permitted and documented, and adverse events are prospectively assessed. Clinical utility endpoints quantify care impact and timeliness: (1) rate of treatment plan changes (e.g., initiation or modification of anticoagulants or antiarrhythmic drugs, cardioversion scheduling, device implantation, or other actions); (2) time to recognition (days) of major arrhythmias-atrial fibrillation (AF), ventricular tachycardia (VT), pause, ventricular premature complex (VPC), and supraventricular tachycardia (SVT)-based on MEMO-Cue alarms or MEMO-Care results with objective confirmation; (3) reduction ratio in recognition time when identified earlier by MEMO-Cue versus MEMO-Care; and (4) proportion of participants with shortened recognition time by MEMO-Cue. Clinical performance endpoints assess detection characteristics and agreement between MEMO-Cue alarms and MEMO-Care findings: (1) clinical sensitivity (true positive / \[true positive + false negative\]); (2) precision, i.e., positive predictive value (true positive / \[true positive + false positive\]); and (3) positive concordance rate (proportion of MEMO-Care-detected arrhythmias alerted by MEMO-Cue). Safety is captured as treatment-emergent adverse events after device application, including device-related skin reactions, detachment, or signal dropouts, with severity graded per NCI-CTCAE v5.0 and relationship to device recorded. By characterizing real-time patch-based telemetry alongside analytic review and its influence on diagnostic timing and management, the study aims to generate practical evidence supporting feasibility, reliability, and workflow compatibility of single-lead patch telemetry for in-hospital ECG monitoring.

Status (registry)
Not yet recruiting
Study type
Interventional
Enrollment
100 (estimated)
First submitted
14 Nov 2025
Start date
Dec 2025
Primary completion date
May 2026
Lead sponsor
Yonsei University
NCT number
NCT07260721

What you commit to

  • Study type: Interventional
  • Planned participants: 100
  • From Dec 2025 to the primary completion date, May 2026
  • 1 site in 1 country
  • Visits and tests: ask the trial team, the registry does not list them

Built from the registry fields of ClinicalTrials.gov. It describes the study, not your situation.

Who cannot take part

Copied verbatim from ClinicalTrials.gov and grouped by topic. Only the trial team decides who can take part.

Prior treatment

  • Presence of skin wounds at the intended application site of the investigational device.

Other illness

  • Known hypersensitivity or allergic reaction to adhesives or hydrogel.
  • Implanted cardiac electronic devices such as pacemakers, ICDs, or other CIEDs
  • Current or past history of skin cancer, rash, dermatologic disorders, keloid formation, or skin injury.
  • Any condition judged by the investigator to increase risk or make participation inappropriate.
  • Cognitive impairment that precludes understanding of study information or voluntary consent.

Who the study is looking for

  • Adults aged 19 years or older who provide written informed consent for participation.
  • Patients requiring in-hospital telemetry electrocardiogram monitoring during hospitalization.

Age in the registry: 19 years to - · Sex: All · Does not accept healthy volunteers

Full criteria on ClinicalTrials.gov

Sites (1)

Sites in registry order. Pick your city on the disease page to sort them by distance.

SiteCityCountrySite status
Yonsei University College of Medicine
Coordinator of this site? Confirm its status
SeoulSouth KoreaUnknown status