Inter- and Intra-Rater Reliability of a Wearable Inertial Sensor for Spatiotemporal Gait Assessment in Stroke Survivors

Source: ClinicalTrials.gov · Last updated 16 Jun 2026

Brief summary (registry, in English)

Background and Objective: Stroke frequently impairs gait functionality, leading to significant limitations in functional independence and quality of life. Objective gait analysis is essential for evaluating clinical status and rehabilitation progress. While laboratory-bound, non-wearable systems are considered the gold standard, their high cost, complex infrastructure, and requirement for specialized personnel limit their routine implementation in daily clinical practice. Portable inertial measurement units have emerged as a practical, low-cost alternative for motion analysis outside traditional laboratory settings. However, evidence regarding specific commercial devices in pathological populations remains limited. This study aims to evaluate the inter-rater and intra-rater reliability of the commercially available Baiobit® lumbar-mounted inertial sensor for measuring spatiotemporal gait parameters in stroke survivors. Methodology: A prospective, single-group, repeated-measures design was conducted at a specialized neurorehabilitation clinic (Neuron Clinic, Madrid). A convenience sample of 22 adults diagnosed with subacute or chronic stroke who were able to ambulate independently was included. Gait assessments were performed by two trained evaluators across two separate sessions spaced 24 to 48 hours apart. During each session, the Baiobit® sensor was secured to the participants' sacral region (S1-S2) using an adjustable belt. Participants performed three 10-meter walking trials at their comfortable, self-selected pace for each evaluator. Reliability was quantified using Intraclass Correlation Coefficients (ICC), Standard Error of Measurement (SEM), and Minimal Detectable Change (MDC). Expected Outcomes: It is hypothesized that the Baiobit® inertial sensor will demonstrate adequate relative and absolute inter- and intra-rater reliability across spatiotemporal gait parameters, supporting its viability as an objective monitoring tool in routine stroke rehabilitation clinical settings.

Status (registry)
Completed
Study type
Observational
Enrollment
24 (actual)
First submitted
10 Jun 2026
Start date
10 Oct 2025
Primary completion date
20 Apr 2026
Lead sponsor
Neuron, Spain
Diseases
Stroke
NCT number
NCT07650331

What you commit to

  • Study type: Observational
  • Participants enrolled: 24
  • From 10 Oct 2025 to the primary completion date, 20 Apr 2026
  • 1 site in 1 country
  • Visits and tests: ask the trial team, the registry does not list them

Built from the registry fields of ClinicalTrials.gov. It describes the study, not your situation.

Who cannot take part

Copied verbatim from ClinicalTrials.gov and grouped by topic. Only the trial team decides who can take part.

Prior treatment

  • concomitant neurological conditions other than stroke
  • recent use of substances or medications that impair bait, balance, or postural control

Other illness

  • clinical instability or acute medical conditions that compromise gait safety
  • severe musculoskeletal disorders that interfere with gait analysis

Other

  • balance or coordination impairments secondary to visual or auditory deficits
  • pregnancy
  • cognitive or behavioral impairments that prevent the proper performance of the test

Who the study is looking for

  • adults aged 18-85 years
  • confirmed diagnosis of stroke
  • ability to ambulate (FAC \> 4), regardless of foot-up use
  • Capacity to walk 10m without stopping and repeat the trials 6 times across the session
  • Cognitive ability to understand the study instruction and provide written informed consent

Age in the registry: 18 years to 85 years · Sex: All · Does not accept healthy volunteers

Full criteria on ClinicalTrials.gov

Sites (1)

Sites in registry order. Pick your city on the disease page to sort them by distance.

SiteCityCountrySite status
Neuron Madrid Río
Coordinator of this site? Confirm its status
MadridSpainUnknown status

This page is information, not medical advice. Discuss any trial with your doctor.