Comparing Two Balloon Inflation Methods When Placing Heart Stents

Compares how long a balloon is inflated to open heart arteries for stents in adults.

Plain-language title generated from the registry record
Registry title: Rapid Inflation/Deflation Compared With Prolonged High-Pressure Balloon Inflation

Key facts

Where
Little Rock, United StatesSee the site

Where in United States

  • John L McClellan Memorial Veterans HospitalLittle Rock, United StatesNo longer taking part

Questions to ask the study team

  1. How often do I need to come in, and for how long each time?
  2. Are travel costs paid?
  3. Can I keep my own doctor?
  4. What happens if I want to stop?
Print a page for my doctor

Trial details

Who runs it
Central Arkansas Veterans Healthcare System
Trial code
NCT01952873
Record updated
21 October 2026
Original description
It is universally accepted that high-pressure balloon inflation is required to most effectively deploy a coronary balloon-expandable stent. However, there is not consensus nor are there any guidelines regarding the method of balloon inflation, particularly the duration of inflation. Underexpansion and strut malapposition after stent deployment are among the most powerful predictors for adverse vessel outcomes. High-pressure inflation for stent deployment is effective to optimally expand the stent, but unlike in vitro testing in air, there are poorly distensible plaque elements that may not instantaneously yield to the balloon pressure. However, these elements may ultimately yield to prolonged inflation. Most clinical interventional cardiologists inflate for a relatively short period (15-30 sec). The investigators have noted that when balloon pressure is maintained at a certain pressure level it tends to decrease over time, and may require 60-180 or more seconds to maintain pressure stability. This finding implies that plaque elements are yielding slowly over time to the increased pressure, thus increasing expansion, and suggests that a prolonged inflation until balloon pressure stabilizes is more effective than a rapid inflation/deflation sequence to fully expand and appose the stent to the vessel wall. At present there is no consensus on stent deployment strategy. It is our hypothesis that prolonged inflation is superior to the more commonly used strategy of rapid inflation/deflation.Read full original descriptionShow less

Rapid Inflation/Deflation Compared With Prolonged High-Pressure Balloon Inflation on the Results of Stent Deployment

It is universally accepted that high-pressure balloon inflation is required to most effectively deploy a coronary balloon-expandable stent. However, there is not consensus nor are there any guidelines regarding the method of balloon inflation, particularly the duration of inflation. Underexpansion and strut malapposition after stent deployment are among the most powerful predictors for adverse vessel outcomes. High-pressure inflation for stent deployment is effective to optimally expand the stent, but unlike in vitro testing in air, there are poorly distensible plaque elements that may not instantaneously yield to the balloon pressure. However, these elements may ultimately yield to prolonged inflation. Most clinical interventional cardiologists inflate for a relatively short period (15-30 sec). The investigators have noted that when balloon pressure is maintained at a certain pressure level it tends to decrease over time, and may require 60-180 or more seconds to maintain pressure stability. This finding implies that plaque elements are yielding slowly over time to the increased pressure, thus increasing expansion, and suggests that a prolonged inflation until balloon pressure stabilizes is more effective than a rapid inflation/deflation sequence to fully expand and appose the stent to the vessel wall. At present there is no consensus on stent deployment strategy. It is our hypothesis that prolonged inflation is superior to the more commonly used strategy of rapid inflation/deflation.

Optimal coherence tomography (OCT), a novel technology that measures near-infrared light reflections and translates them into a 2D image, has an axial resolution nearly 10-times that of intravascular ultrasound (IVUS). Thus it is possible to examine the extent of stent malposition and stent expansion using this modality.

The current randomized trial tests the hypothesis that prolonged balloon inflation until a stable balloon pressure is maintained is more effective than a rapid inflation/deflation sequence when performed to the same balloon inflation pressure.

Inclusion: Patients >18 years old with coronary disease with clinical indication for single stent placement in a lesion with a 2.5-3.5 mm diameter and who require OCT for determination of effective stent placement .

Exclusion: ST segment elevation myocardial infarction 2. Chronic total occlusion 3. Bifurcation lesion or major side branch (>2.5 mm) within the stented area 4. Need for overlapping stents 5. Clinical instability including cardiogenic shock 6. Inability to give informed consent 7. Chronic kidney disease with serum creatinine >1.8 mg/dL 8. Unprotected left main stenosis; -.

ClinicalTrials.gov NCT01952873