Custom stent grafts for aneurysms and other serious aorta problems
Tests custom-made aortic grafts in adults with complex aortic aneurysms and related conditions.
Key facts
- Who runs it
- University of Alabama at Birmingham
- Where
- Birmingham, United StatesSee the site
- Trial code
- Registry title
- Evaluation of the Cook Custom Aortic Endograft, the Zenith t-Branch Endovascular Graft, and Surgeon-Modified Endograft in Treating Aortic Pathologies
- Status
- Recruiting
- People taking part
- 410 people, planned
- Started
- Jun 2014
- Expected to end
- Oct 2027
- Type of study
- Interventional, 3 groups
- Treatments tested
- Cook Custom Aortic Endograft
- Zenith t-Branch Endovascular Graft
- Surgeon-Modified Endograft
- Record updated
- 6 January 2026
Who can take part
AI summary
From the trial's eligibility criteria. Machine-read from the registry text on this page, so it can be wrong. The registry text below and the trial team decide who can take part.
The trial is looking for adults with complex aortic disease near the kidney, gut or arch arteries. They are treated with custom or modified stent-grafts placed through the blood vessels.
- Age
- 18 years and older
- Sex
- All sexes
- Disease stage
- Juxtarenal, suprarenal, thoracoabdominal or aortic arch aneurysm, penetrating aortic ulcer or aortic dissection, in people with stable blood pressure and circulation. Aneurysms over 5.5 cm (2.2 in) without symptoms, or 5.0 cm (2 in) with growth over 0.5 cm (0.2 in) in 6 months, or any size if ruptured or symptomatic. Ulcers over 2.0 cm (0.8 in) deep. Dissections must be subacute (>14 days) or chronic (>20 days) with widening of the aorta.
Main reasons for not taking part
- Life expectancy under 12 months, or pregnant, breastfeeding or planning pregnancy within 60 months
- Allergy to device materials (stainless steel, polyester, solder, gold, nitinol) or severe contrast reaction
- Infection, or aortic disease caused by infection or by a sudden injury
- eGFR < 30 mL/min and not on dialysis
- Unstable angina, irreversible bleeding disorder, or blood vessel shape or size that blocks the device
The registry criteria, word for word
Show all 35 criteriaShow less
Who can take part
- Juxtarenal, suprarenal, and thoracoabdominal aortic pathology as follows in hemodynamically stable patients:; Intact or contained ruptured aortic or aortoiliac aneurysms (atherosclerotic/degenerative or saccular) involving or in close approximation to the visceral segment of the aorta; Diameter > 5.5 cm if asymptomatic, or 5.0 cm with enlargement of > 0.5 cm in 6 months; History of growth > 0.5 cm per year; Any size if ruptured or symptomatic; Penetrating aortic ulcer (PAU); > 2.0 cm in depth; Any size if contained ruptured or symptomatic; Subacute (>14 days) or chronic (>20 days) aortic dissection with aneurysmal degeneration with at least one of the following:; Total aortic diameter > 5.5 cm if asymptomatic; Total aortic diameter > 4.5 cm if symptomatic; Total aortic diameter > 5.0 cm and history of growth > 0.5 cm in 6 months
- Aortic Arch pathology:; Aneurysm, Ascending thoracic aortic pseudoaneurysm, Type A thoracic aortic dissection, Retrograde type A thoracic aortic dissection between the Sinus of Valsalva and the innominate artery orifice (without involvement of the Aortic Valve), or Ascending penetrating aortic ulcer with and without intramural hematoma; Suitable iliac artery and brachial artery access; Absence of severe landing zone (> 90 degree) angulation that would preclude necessary device delivery/seal/fixation; Suitable iliac artery access to accommodate device delivery system; Target arteries for arch branches:; < 24 mm diameter; Adequate landing zone length to obtain proximal and distal seal; Free from dissection precluding adequate seal in distal landing zone of branch stent and severe tortuosity/thrombus/calcification
- Aortic Arch Aneurysm; Proximal aortic fixation zone:; Native aorta or surgical graft; Diameter: 20 - 42 mm; Proximal neck length > 20 mm; Must occur distal to coronary arteries and any coronary artery bypass grafts that are considered patent and necessary for proper cardiac perfusion; Distal aortic fixation zone:; Native aorta or surgical graft; Diameter: 20 - 44 mm; Distal neck length > 20 mm. However, if dissection, distal graft may land in dissected aorta; Supra-aortic trunk (brachiocephalic) vessels (Any combination of arteries may be used for repair) A. Innominate artery; Native vessel or surgical graft; Diameter: 8 - 22 mm; Length of sealing zone > 10 mm; Acceptable tortuosity B. Left (or right) common carotid artery; <!-- -->; Native vessel or surgical graft; Diameter 5 - 20 mm; Length of sealing zone > 10 mm C. Left (or right) subclavian artery; <!-- -->; Native vessel or surgical graft; Diameter 5 - 20 mm; Length of sealing zone > 10 mm
- Aortic Dissection; Access into the true lumen from the groin and at least one supra-aortic trunk vessel; Seal zone in the target aorta (or surgical graft) that is proximal to the primary dissection, such that a stent-graft would be anticipated to seal off the dissection lumen; Seal zone in the target supra-aortic trunk vessels that is distal to the dissection, anticipated to seal off the dissection lumen or surgically created; True lumen size large enough to deploy the device and still gain access into the target branch; General Exclusion Criteria:
- Less than 18 years of age
- Life expectancy less than 12 months based on the surgeon's assessment
- Pregnant or breastfeeding or planning on becoming pregnant within 60 months
- Inability or refusal to give informed consent
- Unwilling or unable to comply with the follow-up schedule
- Less than 30 days beyond primary endpoint for other investigative drug or device study; Medical Exclusion Criteria:
- Known allergy to the device components (i.e. stainless steel, polyester, solder, gold, or nitinol)
- History of anaphylactic reaction to contrast material that cannot be adequately premedicated
- Systemic or local infection that may increase the risk of endovascular graft infection
- Baseline eGFR < 30 mL/min (calculated by the Modification of Diet in Renal Disease formula) and not on hemo- or peritoneal dialysis. If the patient is currently on dialysis, or is currently planning on initiating dialysis, then they may undergo repair
- Body habitus that would inhibit X-ray visualization of the aorta
- Major surgical or interventional procedure unrelated to the treatment of the aneurysm planned ≤ 30 days of the endovascular repair
- Unstable angina, defined as a progressive increase in symptoms, new onset at rest or nocturnal angina, or onset of prolonged angina
- Irreversible coagulopathy; Anatomical Exclusion Criteria:
- Aortic transection due to acute trauma
- Infectious ("mycotic") etiology of the aortic disease
- Significant occlusive disease or tortuosity precluding delivery of the device components
- Juxtarenal, Suprarenal, and Thoracoabdominal:
- Proximal Landing zone < 20 mm in length. The proximal landing zone can be within zones 2 through 8, with least 20 mm of proximal seal and fixation in aorta or Dacron
- Proximal neck, defined as the thoracic aorta distal to the native left carotid artery, measured outer wall to outer wall on a sectional image (CT) > 41 mm in diameter or < 18 mm in diameter
- Distal landing zone < 20 mm in length if the landing zone is in the aorta, or < 20 mm if the landing zone is in the iliac arteries or in Dacron (in the event the patient has had a previous or concomitant aortic or aorto-iliac reconstruction)
- Untreatable branch vessel stenosis
- Anatomy that would not allow maintenance of at least one patent hypogastric artery
- Signs that the inferior mesenteric artery (IMA) is indispensable (i.e. angiographic visualization or a large IMA, filling of superior mesenteric artery (SMA) via collaterals, stenosis of celiac or SMA or oblique views) and the indispensable IMA is not amenable to treatment with a graft branch or fenestration
- Branching, duplication, aneurysm or untreatable stenosis of the celiac, SMA or renal arteries that would preclude implantation of the investigational devices
- Aortic arch:
- Proximal neck > 44 mm or < 28 mm in diameter
- Inadequate landing zone to allow adequate distal seal of exclusion of false lumen perfusion in dissection
- Untreatable branch vessel stenosis
- Significant occlusive disease, tortuosity, or calcification that would prevent endovascular access
- Patients qualifying for an industry-sponsored study allowing for a similar repair will be enrolled in the industry-sponsored study
Where in United States
- University of Alabama at BirminghamBirmingham, United StatesContact: Adam W Beck, MDTaking people
About the trial
What the trial wants to find out
This is a single-center study to evaluate the safety and effectiveness of three investigational devices, the Cook Custom Aortic Endograft, the Zenith t-Branch Endovascular Graft, and the Surgeon-Modified Endografts in the treatment of Juxtarenal, Suprarenal, Thoracoabdominal, and Aortic Arch pathologies involving the at least one brachiocephalic artery or visceral vessels.
Read full original descriptionShow less
The three investigational devices offer an endovascular approach to treat complex aortic pathologies that cannot be treated with commercially available devices. This customized, endovascular approach has the potential to decrease hospital length of stay, pulmonary complications, and in-hospital mortality.
The 3 groups in the trial
- Cook Custom Aortic EndograftTreatment being tested
Participants will receive the following: (Juxtarenal, Suprarenal, Thoracoabdominal) Clinical Exam, Blood Tests, CT Scans (with and without contrast) or Ultrasound, Abdominal Device X-ray, and Angiography. (Aortic Arch) Clinical Exam, Neurological Exam, Blood Tests, Echocardiogram, CT Scans (with and without contrast), Chest X-ray, and Angiography. These tests will aid in the design of the Cook Custom Aortic Endograft. The Cook Custom Aortic Endograft has a variable design such that seal and fixation may be obtained proximal and distal to pathology in the juxtarenal aorta, suprarenal aorta, thoracoabdominal aorta, or the aortic arch aorta. Grafts may include a combination of up to 5 fenestrations and/or branches.
- Zenith t-Branch Endovascular GraftTreatment being tested
Participants will receive the following: Clinical Exam, Blood Tests, CT Scans (with and without contrast) or Ultrasound, Abdominal Device X-ray, and Angiography. These tests will aid in the sizing of the the Zenith t-Branch Endovascular Graft. The Zenith t-Branch Endovascular Graft is a tubular graft with four branches and a covered stent at the proximal end that contains barbs for proximal fixation of the device. The graft is designed to be connected with celiac, superior mesenteric and two renal arteries via self-expanding covered bridging stents.
- Surgeon-Modified EndograftTreatment being tested
Participants will receive the following: Clinical Exam, Blood Tests, CT Scans (with and without contrast) or Ultrasound, Abdominal Device X-ray, and Angiography. These tests will aid in the design of the Surgeon-Modified Endografts. These will be created in the operating room by modifying a commercially-available Cook Alpha Thoracic Endograft or Cook Zenith Infrarenal Aortic Device such that seal and fixation may be obtained proximal and distal to pathology in the juxtarenal aorta, suprarenal or thoracoabdominal aorta. Grafts may include a combination of up to 5 fenestrations and branches.
Questions to ask the study team
- How often do I need to come in, and for how long each time?
- Are travel costs paid?
- Can I keep my own doctor?
- What happens if I want to stop?
Contact the study team: see the registry record → Contacts and Locations
Print a page for my doctorData and sources
- Registry record
- Listed on ClinicalTrials.gov.How to verify a trial in the registry
- Official title
- Evaluation of All-Cause Mortality and Pulmonary Morbidity in Treating Juxtarenal, Suprarenal, Thoracoabdominal, and Aortic Arch Pathologies Using Cook Custom Aortic Endografts, the Zenith t-Branch Endovascular Graft, and the Surgeon-Modified Endograft
- Plain-language title
- Custom stent grafts for aneurysms and other serious aorta problemsGenerated from the registry record. The registry title is the official one.
- AI summary
- From the trial's eligibility criteria. Read by machine on 14 November 2026.
- Publications
- Multicenter Prospective Evaluation of Patient Radiation Exposure During Fenestrated-branched Endovascular Aortic Repair: A Ten-year Experience.Annals of surgery, 2026
- Trends and outcomes over time with fenestrated and branched endovascular aortic repair in the United States Aortic Research Consortium.Journal of vascular surgery, 2025
- Early and Late Aortic-Related Mortality and Rupture After Fenestrated-Branched Endovascular Aortic Repair of Thoracoabdominal Aortic Aneurysms: A Prospective Multicenter Cohort Study.Circulation, 2024
- Severity of acute kidney injury is associated with decreased survival after fenestrated and branched endovascular aortic aneurysm repair.Journal of vascular surgery, 2023
- Predictors and outcomes of spinal cord injury following complex branched/fenestrated endovascular aortic repair in the US Aortic Research Consortium.Journal of vascular surgery, 2023
- Record updated
- 6 January 2026