Evaluation of the GORE® TBE Device in the Treatment of Lesions of the Aortic Arch and Descending Thoracic Aorta, Zone 2
Key facts
- Where
- Ann Arbor, Atlanta, Austin, Baltimore, Boston, Buffalo, Camden, Charlotte, Chicago, Cleveland, Durham, Gainesville, Hartford, Houston, Indianapolis, Lebanon, Los Angeles, Louisville, Madison, Memphis, Nashville, Norfolk, Philadelphia, Pittsburgh, Plano, Portland, Rochester, Seattle, St Louis, Stanford, Tampa, and Washington D.C., United StatesSee the 35 sites
Where in United States
- University of MichiganAnn Arbor, United StatesNo longer taking part
- Emory UniversityAtlanta, United StatesNo longer taking part
- Cardiothoracic and Vascular SurgeonsAustin, United StatesNo longer taking part
- University or Maryland BaltimoreBaltimore, United StatesNo longer taking part
- Massachusetts General HospitalBoston, United StatesNo longer taking part
- Research Foundation SUNY BuffaloBuffalo, United StatesNo longer taking part
- Cooper University HospitalCamden, United StatesNo longer taking part
- Carolinas HealthCare SystemsCharlotte, United StatesNo longer taking part
- Northwestern UniversityChicago, United StatesNo longer taking part
- Cleveland ClinicCleveland, United StatesNo longer taking part
- Duke University Medical CenterDurham, United StatesNo longer taking part
- University of Florida - GainesvilleGainesville, United StatesNo longer taking part
- Hartford HospitalHartford, United StatesNo longer taking part
- Baylor College of Medicine, HoustonHouston, United StatesNo longer taking part
- Houston Methodist HospitalHouston, United StatesNo longer taking part
- Memorial HermannHouston, United StatesNo longer taking part
- St. Vincent Medical Group, Inc.Indianapolis, United StatesNo longer taking part
- Dartmouth Hitchcock Medical CenterLebanon, United StatesNo longer taking part
- Cedar Sinai Medical CenterLos Angeles, United StatesNo longer taking part
- Keck Medical Center of USCLos Angeles, United StatesNo longer taking part
- University of Louisville Jewish HospitalLouisville, United StatesNo longer taking part
- University of Wisconsin SystemMadison, United StatesNo longer taking part
- Cardiovascular Surgery ClinicMemphis, United StatesNo longer taking part
- Vanderbilt University Medical CenterNashville, United StatesNo longer taking part
- Sentara Medical GroupNorfolk, United StatesNo longer taking part
- Hospital of the University of PennsylvaniaPhiladelphia, United StatesNo longer taking part
- University of Pittsburgh Medical CenterPittsburgh, United StatesNo longer taking part
- Heart Hospital at Baylor PlanoPlano, United StatesNo longer taking part
- Oregon Health Science UniversityPortland, United StatesNo longer taking part
- Mayo Clinic - RochesterRochester, United StatesNo longer taking part
- University of WashingtonSeattle, United StatesNo longer taking part
- Washington University School of MedicineSt Louis, United StatesNo longer taking part
- Leland Stanford Junior UniversityStanford, United StatesNo longer taking part
- Univeristy of South FloridaTampa, United StatesNo longer taking part
- Medstar Health Research InstituteWashington D.C., United StatesNo longer taking part
Trial details
- Who runs it
- W.L.Gore & Associates
- Trial code
- NCT02777593
- Record updated
- 10 September 2026
- Original description
The objective of this study is to determine whether the GORE® TAG® Thoracic Branch Endoprosthesis is safe and effective in treating lesions of the aortic arch and descending thoracic aorta, requiring Zone 2 proximal implantation of the device.Read full original descriptionShow less
Evaluation of the GORE® TAG® Thoracic Branch Endoprosthesis (TBE Device) in the Treatment of Lesions of the Aortic Arch and Descending Thoracic Aorta, Zone 2
The objective of this study is to determine whether the GORE® TAG® Thoracic Branch Endoprosthesis is safe and effective in treating lesions of the aortic arch and descending thoracic aorta, requiring Zone 2 proximal implantation of the device.
Inclusion: Presence of thoracic aortic pathology deemed to warrant surgical repair which requires proximal graft placement in Zone 0-2; Age ≥18 years at time of informed consent signature; Subject is capable of complying with protocol requirements, including follow-up; Informed Consent Form (ICF) is signed by Subject or legal representative; Must have appropriate proximal aortic landing zone; Must have appropriate target branch vessel landing zone; For patients with aneurysm/isolated lesion, must have appropriate distal aortic landing zone.
Exclusion: Concomitant disease of the ascending aorta or aneurysm of the abdominal aorta requiring repair; Previous endovascular repair of the ascending aorta; Previous endovascular repair of the DTA with a non-Gore device; Surgery within 30 days prior to enrollment, with the exception of surgery for Ascending Aortic Dissection and/or placement of vascular conduit for access; Myocardial infarction within 6 weeks prior to treatment; Stroke within 6 weeks prior to treatment, stroke defined as rapidly developing clinical signs of focal (or global) disturbance of cerebral function, lasting more than 24 hours or leading to death, with no apparent cause other than that of vascular origin; Participation in another drug or medical device study within one year of study enrollment; Previous instance of Heparin Induced Thrombocytopenia type 2 (HIT-2) or known hypersensitivity to heparin; Infected aorta; Patient has a systemic infection and may be at increased risk of endovascular graft infection; Degenerative connective tissue disease, e.g. Marfan's or Ehler-Danlos Syndrome; Known history of drug abuse within one year of treatment; Patient has known sensitivities or allergies to the device materials; Patient has known hypersensitivity or contraindication to anticoagulants or contrast media, which is not amenable to pre-treatment; Patient with a history of a hypercoagulability disorder and/or hypercoagulability state; Patient has body habitus or other medical condition which prevents adequate visualization of the aorta; Renal failure defined as patients with an estimated Glomerular Filtration Rate (eGFR) <30 or currently requiring dialysis; Life expectancy <2 years; Pregnant female at time of informed consent signature; Presence of protruding and/or irregular thrombus and/or atheroma in the aortic arch or ascending aorta; Tortuous or stenotic iliac and/or femoral arteries preventing introducer sheath insertion and the inability to use a conduit for vascular access; Planned coverage of celiac artery; Diameter taper outside of the device sizing range between proximal and distal landing zones of aorta and the inability to use additional devices of different diameters to compensate for the taper; Mycotic aneurysm; Persistent refractory shock (systolic blood pressure <90 mm Hg).