Under construction – not a live service
Sign in
CompletedNo phase

FLExAbility Sensor Enabled Substrate Targeted Ablation for the Reduction of VT Study

Key facts

Who runs it
Abbott Medical Devices
Where
Ann Arbor, Atlanta, Aurora, Austin, Baltimore, Birmingham, Charleston, Chicago, Fort Lauderdale, Hollywood, Houston, Los Angeles, Minneapolis, Nashville, Philadelphia, Raleigh, Rochester, San Diego, Seattle, Tampa, and The Woodlands, United StatesSee the 23 sitesAlso in 7 other countries, 9 sites
Trial code
Status
Completed
People taking part
592 people enrolled
Started
1 Jun 2018
Ended
11 Apr 2024
Type of study
Interventional, 3 groupsOne group gets an existing treatment, for comparison.
Treatments tested
  • Market Approved RF Ablation System
  • FlexAbility SE Ablation Catheter
Record updated
8 January 2025

Who can take part

Age
18 years and older
Sex
Women and men
Healthy volunteers
Cannot take part

The registry criteria, word for word

Show all 31 criteriaShow less

Who can take part

  • Structural heart disease (ischemic or non-ischemic) with one of the following:; Confirmed diagnosis via echocardiography and/or cardiac CT/MRI [computed tomography/magnetic resonance imaging], or; Left ventricular ejection fraction (EF) <40% (documented within the last 6 months via echocardiography, or; Arrhythmogenic RV [right ventricular] cardiomyopathy/dysplasia (per 2010 ARVC/D [arrhythmogenic right ventricular cardiomyopathy/dysplasia] Task Force Criteria).27
  • At least one documented episode of sustained MMVT by either EGM [cardiac electrogram] or ECG [electrocardiogram] in the 6 months prior to enrollment
  • Implanted with a market released ICD [implantable cardioverter-defibrillator] or CRT-D [cardiac resynchronization therapy-defibrillator] for at least 30 days prior to index ablation procedure
  • Refractory (i.e. not effective, not tolerated or not desired) to at least one anti-arrhythmic medication (either amiodarone or sotalol) for treatment of MMVT
  • At least 18 years of age
  • Informed of the nature of the study, agreed to its provisions and has provided written informed consent as approved by the Institutional Review Board/Ethics Committee (IRB/EC) of the respective clinical study site
  • Able and willing to comply with all study requirements

Who cannot take part

  • Currently receiving support, or anticipated to receive support prior to the index ablation procedure, via extracorporeal membrane oxygenation (ECMO)
  • Presence of intracardiac thrombus verified via computer tomography (CT), magnetic resonance imaging (MRI), transesophageal echocardiogram (TEE), or transthoracic echocardiogram (TTE) within 48 hours prior to the index ablation procedure or intra-procedure intracardiac echocardiography (ICE); o For subjects with a history of AF [atrial fibrillation], this verification must be done via TEE or ICE
  • ST elevation myocardial infarction (MI) within 60 days prior to index ablation procedure
  • Previous cardiac surgery (e.g. ventriculotomy, atriotomy, coronary artery bypass graft), within 60 days prior to index ablation procedure
  • Percutaneous coronary intervention (PCI) within 30 days prior to index ablation procedure
  • Incessant VT (continuous sustained VT that promptly recurs despite repeated intervention for termination over ≥3 hours) necessitating immediate treatment or requiring hemodynamic support prior to the ablation procedure
  • Contraindication to systemic anticoagulation (i.e. heparin, warfarin, or a direct thrombin inhibitor)
  • Enrolled in an investigational study evaluating another device or drug that would confound the results of this study
  • History of stroke with modified Rankin scale > 3 (See Appendix C)
  • Unstable angina
  • Chronic NYHA [New York Heart Association] Class IV heart failure
  • Active uncontrolled infection
  • Other anatomic or co morbid conditions or other medical, social, or psychological conditions that, in the investigator's opinion, could limit the patient's ability to participate in the study or to comply with follow up requirements, or impact the scientific soundness of the study results
  • Have a life expectancy of less than 12 months due to any condition
  • Ejection fraction < 15%
  • Thrombocytopenia (defined as platelet count <80,000) or coagulopathy
  • Implanted with a subcutaneous ICD
  • Implanted with a ventricular assist device (VAD) (e.g. TandemHeart)
  • Idiopathic VT
  • VT/VF [ventricular tachycardia/ventricular fibrillation] thought to be from channelopathies
  • Reversible cause of VT
  • Severe aortic stenosis or flail mitral valve
  • Mechanical mitral and aortic valve
  • Women who are pregnant or nursing

Where in United States

Also in 7 other countries, 9 sites

  • University of MichiganAnn Arbor, United StatesNo longer taking part
  • Emory University HospitalAtlanta, United StatesNo longer taking part
  • University of Colorado HospitalAurora, United StatesNo longer taking part
  • Texas Cardiac ArrhythmiaAustin, United StatesNo longer taking part
  • Johns Hopkins University HospitalBaltimore, United StatesNo longer taking part
  • Affinity Cardiovascular Specialists, LLCBirmingham, United StatesNo longer taking part
  • University Hospital - Univ. of Alabama at Birmingham (UAB)Birmingham, United StatesNo longer taking part
  • Medical University of South CarolinaCharleston, United StatesNo longer taking part
  • University of ChicagoChicago, United StatesNo longer taking part
  • Broward General Medical CenterFort Lauderdale, United StatesNo longer taking part
  • Memorial Regional HospitalHollywood, United StatesNo longer taking part
  • Texas Heart InstituteHouston, United StatesNo longer taking part
  • Ronald Reagan UCLA Medical CenterLos Angeles, United StatesNo longer taking part
  • USC University HospitalLos Angeles, United StatesNo longer taking part
  • VA Medical Center MinneapolisMinneapolis, United StatesNo longer taking part
  • Vanderbilt Heart and Vascular InstituteNashville, United StatesNo longer taking part
  • Hospital of the University of PennsylvaniaPhiladelphia, United StatesNo longer taking part
  • WakeMed HospitalRaleigh, United StatesNo longer taking part
  • Mayo ClinicRochester, United StatesNo longer taking part
  • University of California at San Diego (UCSD) Medical CenterSan Diego, United StatesNo longer taking part
  • University of WashingtonSeattle, United StatesNo longer taking part
  • University of South FloridaTampa, United StatesNo longer taking part
  • Memorial Hermann HospitalThe Woodlands, United StatesNo longer taking part

About the trial

What the trial wants to find out

This clinical investigation is intended to demonstrate the safety and effectiveness of ventricular ablation therapy using the FlexAbility Sensor Enabled Ablation Catheter in patients with drug-refractory monomorphic ventricular tachycardia in whom ventricular tachycardia recurs despite antiarrhythmic drug therapy or when antiarrhythmic drugs are not tolerated or desired.

The 3 groups in the trial

  • Randomized - ControlExisting treatment, for comparison

    Subjects with ICM and randomized to the Control group will undergo mapping and substrate-based ablation for the treatment of ventricular tachycardia with any of the protocol-specified commercially available ablation catheters indicated for patients with ICM. A protocol-specified commercially available mapping system will be used in conjunction with the control catheter in the ablation procedure. Subjects will be followed for 12 months post-procedure.

    Treatment: Market Approved RF Ablation System

  • Randomized - TreatmentExisting treatment, for comparison

    Subjects with ICM and randomized to the Treatment group will undergo mapping and substrate-based ablation for the treatment of ventricular tachycardia with the investigational FlexAbility SE Catheter. The Ampere Generator, Cool Point Irrigation Pump and the EnSite Precision Cardiac Mapping System or EnSite X EP System will be used in conjunction with the FlexAbility SE catheter in the ablation procedure. Subjects will be followed for 12 months post-procedure.

    Treatment: FlexAbility SE Ablation Catheter

  • Non-randomized - TreatmentTreatment being tested

    Subjects with NICM will undergo mapping and substrate-based ablation for the treatment of ventricular tachycardia with the investigational FlexAbility SE Catheter. The Ampere Generator, Cool Point Irrigation Pump and the EnSite Precision Cardiac Mapping System or EnSite X EP System will be used in conjunction with the FlexAbility SE catheter in the ablation procedure. Subjects will be followed for 12 months post-procedure.

    Treatment: FlexAbility SE Ablation Catheter

Data and sources

Registry record
Listed on ClinicalTrials.gov.
Official title
FLExAbility Sensor Enabled Substrate Targeted Ablation for the Reduction of Ventricular Tachycardia (LESS-VT) Study
Record updated
8 January 2025