Compression Is Life In Cardiac Arrest - Human Study (CILICA-HS).
Key facts
- Who runs it
- University Hospital, Caen
- Where
- France11 sites in 1 countryChoose a country to see its sites
- Trial code
- Status
- Completed
- People taking part
- 51 people enrolled
- Started
- 1 Dec 2019
- Ended
- 1 Aug 2025
- Type of study
- Interventional, 4 groupsOne group gets no study treatment, for comparison.
- Treatments tested
- Guidance of the External Chest Compression
- Rhythm of a relay 4 minutes
- Record updated
- 25 June 2026
Who can take part
- Age
- 18 years and older
- Sex
- Women and men
- Healthy volunteers
- Cannot take part
Show the full registry criteria (11)Hide the full registry criteria
Who can take part
- Major person
- Victim of a cardiorespiratory arrest
- Eligible for inclusion procedure in immediate life emergency
- Affiliated to the social security system
Who cannot take part
- Known incurable disease
- Traumatic cardiac arrest
- Minor person
- Pregnant woman over 6 months old or breastfeeding
- Palliative care in progress
- Decision not to resuscitate from the patient (anticipated directives) or from the medical team
- Impossibility or contraindication to the use of the External Chest Compression guidance system
Where is this trial?
It has sites in one country. Choose a country to see its sites.
About the trial
What the trial wants to find out
The management of out-of-hospital cardiac arrest is complex and multifactorial. With an incidence between 5 and 15 per 10,000 (46,000 patients per year in France) and a survival rate of only 5% to 15%, the room for improvement remains significant even today and is based on fast and optimal care. Thus French and international recommendations insist on the central element of external chest compression (ECC) and especially its quality (Monsieurs KG and Al. Resuscitation 2015; 95: 1-80). Improving the chest compression fraction (CCF) by limiting time without cardiac massage (No-Flow) is a second major point of the recommendations (Vaillancourt C and Al. Resuscitation 2011; 82: 1501-7). The survival of cardiac arrest victims is closely related on this No-Flow time. The principle of the chain of survival (early warning - ECC - defibrillation - resuscitation) implies that the deterioration of a single link threaten the whole of the care. To meet these qualitative needs, ECC guidance devices have been developed. They make possible to improve the quality of the ECC achieved (Hostler D and Al. BMJ 2011; 342d512). Their use is one of the areas of improvement mentioned in the recommendations. Our team studied in simulation the prolonged effects of guidance on the quality of the ECC during a prolonged resuscitation, with encouraging results (Buléon C and Al. Am J Emerg Med 2016; 34: 1754-60). The investigators propose a study evaluating the efficiency of the guidance of the ECC and the impact of the time of relay on the CCF. The investigators formulate two hypotheses that they wish to test simultaneously using a 2x2 factorial design, in a multicenter randomized trial. The first assumption is that a 4-minute relay rate improves the CCF (by reducing the No-Flow time) compared to the currently recommended 2-minute relay rate. The second hypothesis is that a guiding device improves the quality of the ECC.
Read full original descriptionShow less
This study should, over a period of 2 years, include 500 patients with cardiac arrest for whom specialized resuscitation is undertaken. The investigators hope by this study to improve the knowledge on the optimal rhythm of the ECC and to validate "in vivo" the interest for the guidance found on manikin. This study should make it possible to clarify the recommendations with a high level of evidence in this field and thus contribute to improving the prognosis of the victims of an out-of-hospital cardiac arrest.
The 4 groups in the trial
- Unguided 2 minutes (U2)No study treatment, for comparison
The External Chest Compression are performed without guidance of the CPRmeter device (according to the current guidelines). The duration or rhythm of a relay during which a rescuer performs External Chest Compression before being relayed by another rescuer is 2 minutes according to the current guidelines.
- Unguided 4 minutes (U4)Treatment being tested
The External Chest Compression are performed without guidance of the CPRmeter device (according to the current guidelines). The duration or rhythm of a relay during which a rescuer performs External Chest Compression before being relayed by another rescuer is 4 minutes. (Rhythm of a relay 4 minutes)
Treatment: Rhythm of a relay 4 minutes
- Guided 2 minutes (G2)Treatment being tested
The External Chest Compression are performed with guidance of the CPRmeter device. (Guidance of the External Chest Compression) The duration or rhythm of a relay during which a rescuer performs External Chest Compression before being relayed by another rescuer is 2 minutes according to the current guidelines.
Treatment: Guidance of the External Chest Compression
- Guided 4 minutes (G4)Treatment being tested
The External Chest Compression are performed with guidance of the CPRmeter device. (Guidance of the External Chest Compression) The duration or rhythm of a relay during which a rescuer performs External Chest Compression before being relayed by another rescuer is 4 minutes. (Rhythm of a relay 4 minutes)
Treatment: Guidance of the External Chest Compression and Rhythm of a relay 4 minutes
Data and sources
- Registry record
- Listed on ClinicalTrials.gov.How to verify a trial in the registry
- Official title
- Assessment of the Impact of Relay Timing and CPRmeter Guidance on the Quality of External Chest Compression: Compression Is Life In Cardiac Arrest - Human Study (CILICA-HS).
- Publications
- Record updated
- 25 June 2026