Under construction – not a live service
Sign in
Active, not recruitingNo phase

BGP+ Stent as Bridging Stent in BEVAR

Key facts

Who runs it
Marc Bosiers, MD
Where
Germany10 sites in 1 countryChoose a country to see its sites
Trial code
Status
Active, not recruiting
People taking part
118 people, planned
Started
9 Sept 2020
Ended
31 Jul 2025
Type of study
Interventional
Treatments tested
  • BGP+ Stent Graft System as bridging stent
Record updated
9 April 2025

Who can take part

Age
55 years and older
Sex
Women and men
Healthy volunteers
Cannot take part

The registry criteria, word for word

Show all 34 criteriaShow less

Who can take part

  • Patient eligible for elective repair of TAAA with BEVAR in accordance with the applicable guidelines for vascular interventions (e.g. Aneurysm size 6cm or aneurysm growth of >5mm within 6 months or 1cm within 1 year)
  • Patient is willing to comply with specified follow-up evaluations at the specified times
  • Patient is >55 years old
  • Patient understands the nature of the procedure and provides written informed consent, prior to enrolment in the trial; Patient has a projected life-expectancy of at least 12-months
  • Patient needs to have a landing zone in their target vessel of at least 15 mm, and coverage/ wall adaptation of the BGP+ should be obtained for at least 10 mm
  • The access vessel for introduction of the sheath through which the BGP+ will be advanced should be at least 3mm (it should be able to fit a 8F sheath)
  • No early important division branch from the target vessel with risk of coverage
  • Absence of pre-existing dissection in the target vessels
  • Target vessels (renal arteries, superior mesenteric artery, and celiac trunk) for the BGP+ must have a diameter between 5 and 10 mm
  • Aortic endoprosthesis with inner branches (can be hybrid or branches only)
  • Hybrid aortic endoprosthesis with fenestrations and branches (at least 2 and only the target vessels which are connected by a branch shall be treated with a study device within this study)
  • At least one target vessel is bridged with only one BGP+ (relining allowed)
  • Full compliance with all inclusion criteria/exclusion criteria and all intraoperative criteria

Who cannot take part

  • Previously implanted stent in the target vessel
  • Patients for whom antiplatelet therapy, anticoagulants or thrombolytic drugs are contraindicated
  • Any planned surgical intervention/procedure within 30 days of the trial procedure
  • Patient is currently participating in another conflicting investigational drug or device trial that has not completed the entire follow up period
  • Hybrid Approach (endovascular in combination with open surgery)
  • Myocardial infarction or stroke within 3 months prior to the procedure
  • Patients with uncorrected bleeding disorders or heparin induced thrombocytopenia
  • Patients with diffuse distal disease resulting in poor stent outflow
  • Patients with known hypersensitivity to the stent material (L605) and/or PTFE
  • Patients with a connective tissue disorder
  • Patients with an unstable angina pectoris or heart insufficiency NYHA 3 or 4
  • Patients with access vessel which are too tortuous, narrow or any kind of reason that would lead to failure of introducing and advancing an introducer sheath
  • Renal artery with >100° cranial orientation
  • Patients refusing treatment
  • Female patient with childbearing potential not taking adequate contraceptives or currently breastfeeding
  • Patients with rupture or any patient considered to be hemodynamically unstable at onset of procedure
  • Fresh thrombus formation within the last 14 days
  • Patients with mycotic or inflammatory aneurysm
  • Patients with ASA classification 5 or higher
  • Contraindications against contrast enhanced angiography (a.e. massive hyperthyroidism)
  • Patients with increased risk of intraoperative rupture

This trial has no sites in United States.

It has sites in one country. Choose a country to see its sites.

About the trial

What the trial wants to find out

The objective of this clinical investigation is to evaluate, in a controlled setting, the safety and performance of the BGP+ balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent in BEVAR (branched endovascular aortic repair) for complex aortic aneurysms.

The group in the trial

  • BGP+ Stent Graft SystemTreatment being tested

    Application of BeGraft Peripheral Plus (BGP+) Stent Graft System as bridging stent in Branched Endovascular Repair (BEVAR) for complex aortic aneurysms

    Treatment: BGP+ Stent Graft System as bridging stent

Data and sources

Registry record
Listed on ClinicalTrials.gov.
Official title
Physician-Initiated Trial Investigating the BeGraft Peripheral Plus Stent Graft System as Bridging Stent in BEVAR for Complex Aortic Aneurysms
Record updated
9 April 2025