Taking people in United StatesNo phase
NEXUS Aortic Arch Clinical Study to Evaluate Safety and Effectiveness
Key facts
- Who runs it
- Endospan Ltd.
- Where
- Ann Arbor, Atlanta, Aurora, Baltimore, Birmingham, Boston, Carmel, Chapel Hill, Charleston, Charlotte, Chicago, Cincinnati, Cleveland, Durham, Hartford, Kingsport, La Jolla, Nashville, New York, Norfolk, Orlando, Philadelphia, Plano, Portland, Roanoke, Sacramento, St Louis, Stanford, Washington D.C., and Wynnewood, United StatesSee the 31 sitesAlso in 1 other country, 1 site
- Trial code
- Status
- Recruiting
- People taking part
- 110 people, planned
- Started
- 20 Oct 2020
- Expected to end
- Oct 2029
- Type of study
- Interventional, 3 groups
- Treatments tested
- NEXUS Aortic Stent Graft System
- Record updated
- 20 October 2025
Who can take part
- Age
- 18 years and older
- Sex
- Women and men
- Healthy volunteers
- Cannot take part
The registry criteria, word for word
Show all 52 criteriaShow less
Who can take part
- Male and female age ≥ 18
- Proximal/ascending native or previously implanted surgical graft landing zone of appropriate length
- Proximal/ascending native or previously implanted surgical graft landing zone of appropriate diameter
- Distal/descending native landing zone of appropriate length
- Distal/descending native landing zone of appropriate diameter
- Brachiocephalic trunk native landing zone of appropriate length
- Brachiocephalic trunk native landing zone of appropriate diameter
- Appropriate take off angle between the Brachiocephalic Artery and the Aortic Arch perpendicular
- Appropriate aortic arch perpendicular diameter
- Chronic dissection with at least one of the following conditions:; An aortic aneurysm with a maximum diameter ≥ 55 mm; Rapidly expanding false lumen (growth of > 0.5 cm/6 months); Compressed true lumen associated with end organ malperfusion; Symptomatic
- Aneurysm with at least one of the following conditions:; Dilatation of the aortic arch larger than 5 cm in diameter for subject with fusiform aneurysm; Dilatation of the aortic arch is 1.5 times the normal diameter for subjects ascending or descending; Dilation of the aortic arch larger than 2.5 cm for subject with saccular aneurysm; Symptomatic aneurysm of the aortic arch; Aortic diameter growth rate > 5mm per 6 months; Postoperative pseudoaneurysm expanding from anastomotic suture lines
- Penetrating aortic ulcer with at least one of the following:; Symptomatic; Ulcer demonstrates expansion
- Intramural hematoma with at least one of the following:; Symptomatic (persistent pain); Transverse or longitudinal expansion on serial imaging
- In the event of a lesion in the ascending aortic, the proximal/ascending native or previously implanted surgical graft the landing zone must be appropriate
- Femoral / iliac artery diameter as documented by CTA or MRA that allows endovascular access to the diseased site with a 20 Fr. delivery catheter
- Access vessels morphology suitable for endovascular repair in terms of tortuosity, calcification and angulation, documented by CTA/MRA
- Brachial/Axial Artery diameter that allows endovascular access suitable for 7 Fr
- Subject is considered an appropriate candidate for an elective surgery
- Subject is considered to be at high risk for open repair, as determined by the investigator
- Access vessels, iliac/femoral \& brachial/axillary compatible with vascular access techniques (femoral cutdown or percutaneous), devices, and /or accessories
- Subject is willing and able to comply with procedures specified in the protocol and is able to return for follow-up visits as specified by the protocol
Who cannot take part
- Lesions that can be safely treated with TEVAR landing in zone 2 (with or w/o LSA vascularization)
- Received a previous stent or stent graft in the treated area (including planned landing area)
- Required surgical or endovascular treatment of an infra-renal aneurysm at time of implantation
- Planned major surgical or interventional procedure at time of screening, to be performed after the NEXUS™ implantation
- Any major surgical or interventional procedure 6 weeks before the NEXUS™ implantation, exclusive of planned procedures that are needed for the safe and effective placement of the stent graft (e.g. supra-aortic bypass)
- Subject has had a myocardial infarction (MI) or cerebral vascular accident (CVA) within 90 days prior to the planned implantation
- Subject who have a previously implanted surgical wrap of the ascending aorta
- Any medical condition that, according to the investigator's decision, might expose the subject to increased risk by the investigational device or procedure
- Subject with hostile groins/axilla (scarring, obesity, or previous failed puncture) unless conduit are used
- Any other medical, social, or psychological issues that in the opinion of the investigator preclude them from receiving this treatment, or the procedures and evaluations pre- and post- treatment
- Active participation in another clinical study that has not completed primary endpoint(s) evaluation or that clinically interferes with the endpoints in this study, or subject is planning to participate in such study prior to the completion of this study
- Subjects with severe aortic valvular insufficiency as determined by echocardiography
- Known Connective tissue disease (e.g., Marfan's or Ehler's-Danlos syndromes)
- Subject has an active systemic infection at the time of the procedure documented by pain, fever, drainage, positive culture
- An aneurysm that is mycotic, inflammatory or suspected to be infected
- Subject is suffering from unstable angina or NYHA classification III and IV
- Subject has a known hypersensitivity or contraindication to anticoagulants, antiplatelets, or contrast media, which is not amenable to pre-treatment
- Subject with known sensitivities or allergies to the device materials (including Nitinol [NiTi], polyester fabric [PET], tantalum [TA])
- Clinical conditions that severely inhibit x-ray visualization of the Aorta
- Subject has history of bleeding diathesis or coagulopathy that may limit the use of dual antiplatelet or anticoagulant therapy by the decision of the investigator
- Acute renal failure; chronic renal failure (excluding dialysis); Creatinine > 2.00 mg/dl
- Acute dissection
- Required emergent treatment, e.g., trauma, rupture
- Acute vascular injury of the aorta due to trauma
- Aortic rupture or unstable aneurysm
- Mechanical valve that preclude safe delivery of NEXUS™
- Pregnant
- Life expectancy of less than 2 years
- Unsuitable vascular anatomy
- Subjects with severe atherosclerosis, severe calcification or extensive intraluminal thrombus of the aorta or in the brachiocephalic trunk
- Subject with a contraindication to undergo angiography
Where in United States
Also in 1 other country, 1 site
- University of MichiganAnn Arbor, United StatesContact: Jessica WoodfordTaking people
- Emory UniversityAtlanta, United StatesContact: Shaneka DouglasTaking people
- University of ColoradoAurora, United StatesContact: Tien NgoTaking people
- University of MarylandBaltimore, United StatesContact: Kaitlyn MasihTaking people
- University of Alabama BirminghamBirmingham, United StatesContact: Rebecca St. JohnTaking people
- Tufts Medical CenterBoston, United StatesContact: Jessica KleineNo longer taking part
- Ascension St. VincentCarmel, United StatesContact: Jessica KleineNo longer taking part
- University of North CarolinaChapel Hill, United StatesContact: Rebekah RotenTaking people
- Medical University of South CarolinaCharleston, United StatesContact: Natalie KorenTaking people
- Atrium HealthCharlotte, United StatesContact: Madelyn SmythTaking people
- The University Of ChicagoChicago, United StatesContact: MacKenton JohnsonTaking people
- The Lindner Research CenterCincinnati, United StatesContact: Michael WeberTaking people
- University Hospitals Of ClevelandCleveland, United StatesContact: Terence SemenecTaking people
- Duke University Medical CenterDurham, United StatesContact: Jessica KleineNo longer taking part
- Hartford HospitalHartford, United StatesContact: Vicky MacleodTaking people
- Ballad HealthKingsport, United StatesContact: Jessica KleineNo longer taking part
- University of California San Diego Medical CenterLa Jolla, United StatesContact: Kathleen GrohTaking people
- Vanderbilt University Medical CenterNashville, United StatesContact: Lisa SlingerTaking people
- Northwell Health- Lenox Hill HospitalNew York, United StatesContact: Nhan TranTaking people
- The Mount Sinai Medical CenterNew York, United StatesContact: Catherine MarinTaking people
- Sentara Norfolk General HospitalNorfolk, United StatesContact: Amanda AndersonTaking people
- Advent Health OrlandoOrlando, United StatesContact: Jessica KleineNo longer taking part
- University of PennsylvaniaPhiladelphia, United StatesContact: Elizabeth DurhamTaking people
- Baylor Scott and WhitePlano, United StatesContact: Niat TekleTaking people
- Oregon healthPortland, United StatesContact: Amie LorischTaking people
- Carilion ClinicRoanoke, United StatesContact: Yili ZhongTaking people
- UC Davis HealthSacramento, United StatesContact: Jessica KleineNo longer taking part
- Washington University School of MedicineSt Louis, United StatesContact: Laura McDonaldTaking people
- Stanford University School of MedicineStanford, United StatesContact: Tiffany KoyanoTaking people
- MedStar Washington HospitalWashington D.C., United StatesContact: Suman SinghTaking people
- Lankenau Medical CenterWynnewood, United StatesContact: Jessica KleineNo longer taking part
About the trial
What the trial wants to find out
Prospective, non-randomized, multi-center clinical investigation of the NEXUS™ Aortic Arch Stent Graft System (NEXUSTM) for the treatment of thoracic aortic lesions involving the aortic arch with a proximal landing zone, native or previously implanted surgical graft, in the ascending aorta and with a brachiocephalic trunk native landing zone.
The 3 groups in the trial
- Chronic Dissection (arm closed to enrollment)Treatment being tested
Treatment: NEXUS Aortic Stent Graft System
- Penetrating Aortic Ulcer and/or Intramural HematomaTreatment being tested
Treatment: NEXUS Aortic Stent Graft System
- Aneurysm (arm closed to enrollment)Treatment being tested
Treatment: NEXUS Aortic Stent Graft System
Questions to ask the study team
- How often do I need to come in, and for how long each time?
- Are travel costs paid?
- Can I keep my own doctor?
- What happens if I want to stop?
Contact the study team: see the registry record → Contacts and Locations
Print a page for my doctorData and sources
- Registry record
- Listed on ClinicalTrials.gov.
- Official title
- A Multi-arm, Multi-Center, Non-Randomized, Prospective, Clinical Study to Evaluate the Safety and Effectiveness of the NEXUS Aortic Arch Stent Graft System in Treating Thoracic Aortic Lesions Involving the Aortic Arch
- Record updated
- 20 October 2025