Under construction – not a live service
Sign in
Active, not recruitingNo phase

Evaluation of TAVR Using the NAVITOR Valve in a Global Investigation

Key facts

Who runs it
Abbott Medical Devices
Where
Australia, Austria, Denmark, France, Germany, Israel, Italy, Netherlands, Spain, Switzerland, and United Kingdom37 sites in 11 countriesChoose a country to see its sites
Trial code
Status
Active, not recruiting
People taking part
434 people enrolled
Started
13 Jul 2021
Expected to end
28 Feb 2036
Type of study
Interventional
Treatments tested
  • Navitor Transcatheter Aortic valve and FlexNav Delivery system
Record updated
13 April 2026

Who can take part

Age
18 years to 100 years
Sex
Women and men
Healthy volunteers
Cannot take part

The registry criteria, word for word

Show all 22 criteriaShow less

Who can take part

  • Subject who is judged by a Heart Team, including a cardiac surgeon, to be appropriate for transcatheter heart valve intervention therapy, and is deemed to be at intermediate or low risk for open surgical aortic valve replacement (i.e., heart team estimates risk of surgical mortality < 7% at 30 days, considering the Society of Thoracic Surgeons (STS) risk score, overall clinical status, and other clinical co-morbidities unmeasured by the risk calculator). *
  • New York Heart Association (NYHA) Functional Classification of II, III, or IV *
  • Degenerative aortic valve stenosis with echo-derived criteria, defined as:; aortic valve area (AVA) of ≤ 1.0 cm2 (or indexed EOA ≤ 0.6 cm2/m2) AND either mean gradient ≥ 40 mmHg or peak jet velocity ≥ 4.0 m/s or doppler velocity index (DVI) ≤ 0.25. The echocardiogram supporting the qualifying AVA baseline measurement must be performed within 90 days prior to informed consent). *
  • Aortic annulus diameter of 19-30 mm and ascending aorta diameter of 26-44 mm for the specified valve size listed in the IFU, as measured by CT (systolic phase) conducted within 12 months prior to informed consent

Who cannot take part

  • Evidence of an acute myocardial infarction [defined as ST-segment elevation myocardial infarction (STEMI) or non-ST-segment elevation myocardial infarction (NSTEMI) with acute ischemia symptoms and troponin elevation] within 30 days prior to index procedure
  • Any percutaneous coronary or peripheral interventional procedure performed within 30 days prior (except pacemaker or implantable cardioverter defibrillator (ICD) implant) to index procedure or planned within 30 days following the index procedure
  • Active peptic ulcer or upper GI bleeding within 3 months prior to index procedure that would preclude anticoagulation
  • Recent (within 6 months prior to index procedure date) cerebrovascular accident (CVA) or a transient ischemic attack (TIA)
  • Hostile chest or conditions or complications from prior surgery that would make the subject be considered high surgical risk (i.e., mediastinitis, radiation damage, abnormal chest wall, porcelain aorta, adhesion of aorta or internal mammary artery to sternum, etc.) *
  • Untreated clinically significant coronary artery disease requiring revascularization
  • Significant frailty as determined by the heart team (after objective assessment of frailty parameters) that would indicate high or extreme surgical risk *
  • Mixed aortic valve disease (aortic stenosis and aortic regurgitation with predominant aortic regurgitation 3-4+) *
  • Pre-existing prosthetic heart valve or other implant (such as prosthetic ring or transcatheter edge-to-edge repair (TEER) clip) in any valve position * (Note: Subjects with a bioprosthetic aortic valve may be included in the ViV cohort.)
  • Blood dyscrasias as defined: leukopenia (WBC < 3000 mm3), acute anemia (Hb < 9 g/dL), thrombocytopenia (platelet count < 50,000 cells/mm³); history of bleeding diathesis or coagulopathy
  • Renal insufficiency (creatinine > 3.0 mg/dL or eGFR < 30 ml/min/1.73m2) and/ or end stage renal disease requiring chronic dialysis
  • Severe ventricular dysfunction with LVEF < 30% as measured by resting echocardiogram
  • Severe circumferential mitral annular calcification (MAC) which is continuous with calcium in the left ventricular outflow tract (LVOT) *
  • Life expectancy is less than 2 years in the opinion of the Investigator
  • Aortic valve is a congenital unicuspid or congenital bicuspid valve as verified by echocardiography or CT *
  • Severe (greater than or equal to 3+) mitral regurgitation or severe mitral stenosis with pulmonary compromise
  • Minimum access vessel diameter of < 5.0 mm for small FlexNav Delivery System and < 5.5 mm for large FlexNav Delivery System
  • Eccentricity ratio of the annulus < 0.73; Criterion not applicable for valve-in-valve application

This trial has no sites in United States.

It has sites in 11 countries. Choose a country to see its sites.

About the trial

What the trial wants to find out

Evaluation of TAVR using the NAVITOR valve in a Global Investigation.

The group in the trial

  • Primary Analysis CohortTreatment being tested

    Navitor Transcatheter Aortic Valve System Navitor valves (23mm, 25mm, 27mm, 29mm, and 35mm Titan valve), FlexNav Delivery system (small and large) and Navitor Loading System (small, large, and LG+)

    Treatment: Navitor Transcatheter Aortic valve and FlexNav Delivery system

Data and sources

Registry record
Listed on ClinicalTrials.gov.
Official title
VANTAGE Clinical Trial Evaluation of TAVR Using the NAVITOR Valve in a Global Investigation
Record updated
13 April 2026