Taking people in SpainNo phase

Pivotal Study of the Vienna Transcatheter Self Expandable Aortic Valve SE System

Key facts

Where
Barcelona, Madrid, Majadahonda, Málaga, Oviedo, and Valladolid, SpainSee the 8 sites

Where in Spain

  • Hospital Clinic de BarcelonaBarcelona, SpainContact: Ander Regueiro, MDTaking people
  • Hospital de la Santa Creu i Sant PauBarcelona, SpainContact: Lluis A Serra, MDTaking people
  • Hospital Clínico San CarlosMadrid, SpainContact: Luis Nombela, MDTaking people
  • Hospital Universitario Ramón y CajalMadrid, SpainContact: Ángel S Recalde, MDTaking people
  • Hospital Puerta de HierroMajadahonda, SpainContact: Juan Oteo, MDTaking people
  • Hospital Virgen de la VictoriaMálaga, SpainContact: Juan Horacio A Briales, MDTaking people
  • Hospital Universitario Central De AsturiasOviedo, SpainContact: Cesar Morís de La Tassa, MDNot yet recruiting
  • University Clinical Hospital of ValladolidValladolid, SpainContact: Ignacio J Amat-Santos, MDTaking people

Questions to ask the study team

  1. How often do I need to come in, and for how long each time?
  2. Are travel costs paid?
  3. Can I keep my own doctor?
  4. What happens if I want to stop?

Contact the study team: see the registry record → Contacts and Locations

Print a page for my doctor

Trial details

Who runs it
P+F Products + Features GmbH
Trial code
NCT04861805
Record updated
29 June 2025
Original description
This is a prospective, single arm, multicenter study in an cohort of up to 267 patients (up to 100 Roll-ins and 167 patients implanted per protocol) symptomatic patients with severe aortic stenosis who will be followed up for up to 5 years.Read full original descriptionShow less

A Two -Stage First in Human (FIH) Feasibility / Pivotal Study of the Vienna Aortic Valve SE System

This is a prospective, single arm, multicenter study in an cohort of up to 267 patients (up to 100 Roll-ins and 167 patients implanted per protocol) symptomatic patients with severe aortic stenosis who will be followed up for up to 5 years.

Inclusion: Male or Female; Age ≥ 65 years at time of consent; Women of non-childbearing potential; Severe degenerative calcific native aortic valve stenosis with the following criteria assessed either by resting or dobutamine stress TTE:; Aortic valve area (AVA) < 1.0 cm2 or AVA index ≤ 0.6 cm2/m2 and; Jet velocity > 4.0 m/s or mean gradient > 40 mmHg; Symptomatic aortic stenosis (AS), defined as a history of at least one of the following:; Dyspnea that qualifies at NYHA class II or greater; Angina pectoris; Cardiac syncope; Subject is considered at intermediate or high risk for surgical valve replacement based on at least one of the following:; EuroSCORE II ≥ 4% along with assessment of frailty, major organ system dysfunction, and procedure-specific impediments, in accordance with scientific guidelines; Agreement by the Heart Team that subject is at moderate to high operative risk of serious morbidity or mortality with surgical valve replacement; The local Heart Team deems the patient to be eligible for transfemoral TAVI; Perimeter-based aortic annulus diameter between ≥ 18 and ≤ 29 mm measured by computed tomography (CT) analyzed by a core lab; Adequate iliofemoral access with either:; At least one side with minimum vessel diameter ≥ 6.0 mm and acceptable level of vessel calcification and tortuosity for safe placement of the introducer sheath, as analyzed by a core lab, OR; At least one side with minimum vessel diameter ≥ 5.5 and no significant calcification or severe tortuosity for safe placement of the introducer sheath, as analyzed by a core lab; Patient (or legal representative) understands the study requirements and the treatment procedures and provides written informed consent; The patient and the treating physician agree that the patient will return for all required post-procedure follow-up visits.

Exclusion: Evidence of an acute myocardial infarction (MI) ≤ 30 days prior to screening or IMD implantation (defined as Q-wave MI or non-Q-wave MI with total CK elevation ≥ twice normal in the presence of CK-MB elevation and/or troponin elevation); Patient has had a cerebrovascular stroke or TIA within the past 90 days implantation prior to screening or valve implantation; History of any therapeutic invasive cardiac procedure (including balloon aortic valvuloplasty) within 30 days prior to screening or IMD implantation (except for pacemaker implantation which is allowed); Patient has severe peripheral vascular disease:; including aortic aneurysm defined as maximal luminal diameter > 5 cm or with documented presence of thrombus, marked tortuosity, narrowing of the abdominal aorta, severe unfolding of the thoracic aorta or thick [> 5 mm], protruding or ulcerated atheroma in the aortic arch) or; symptomatic carotid or vertebral disease or successful treatment of carotid stenosis within 30 days prior to screening or IMD implantation; Patient with active bacterial endocarditis within 6 months prior to screening or IMD implantation; Patient has a need for emergency surgery for any reason at time of screening or IMD implantation; General:; Patient with significant pulmonary disease (FEV1 < 30%) or currently on home oxygen; Patient has peptic ulcer disease or history of gastrointestinal bleeding within the 3 months prior to screening or IMD implantation; Patient is currently participating in another investigational drug or device study that has not reached its primary endpoint (excluding observational studies); Untreated clinically significant coronary artery disease requiring revascularization at the screening visit; Patient with cardiogenic shock manifested by low cardiac output and hemodynamic instability and vasopressor dependence, or mechanical hemodynamic support; Patient has (echocardiographic/ CT and/or MRI) evidence of intra-cardiac mass, thrombus or vegetation; Patient has a pre-existing prosthetic heart valve in any position (Note: mitral ring is not an exclusion); Any condition considered a contraindication for placement of a bioprosthetic valve (e.g. patient with contraindication to oral antiplatelet therapy); Severe pulmonary hypertension (e.g., pulmonary artery systolic pressure ≥ 60 mmHg); Patients with evidence of an active systemic infection or sepsis; Patient has a known hypersensitivity or contraindication to contrast media, bovine tissue, nitinol (titanium or nickel), contraindication to oral antiplatelet therapy (aspirin, ticlopidine or clopidogrel) or heparin; Patient has a life expectancy of less than 12 months due to non-cardiac, co-morbid conditions based on the assessment of the investigator at the time of enrolment (i.e. the time of informed consent); Severe dementia (resulting in either inability to provide informed consent for the study/procedure, prevents independent lifestyle outside of a chronic care facility, or will fundamentally complicate rehabilitation from the procedure or compliance with follow-up visits); Other medical, social, or psychological conditions that in the opinion of the Investigator precludes the patient from appropriate consent or adherence to the protocol required follow-up exams; Severe left ventricular dysfunction with left ventricular ejection fraction (LVEF) < 20% by echocardiography, contrast ventriculography, or radionuclide ventriculography; Patient with renal insufficiency (eGFR < 30 ml/min per the Cockcroft-Gault formula) and/ or renal replacement therapy and/ or has serum creatinine level > 3.0 mg/dL or 265 µmol/L replacement therapy at the time of screening; Patient has a haemoglobin < 9 g/dL, platelet count < 50,000 cells/mm3 or > 700.000 cells/mm3, or white blood cell count < 1.000 cells/mm3, history of bleeding diathesis or coagulopathy; Cardiovascular System:; Patient has a congenital unicuspid or bicuspid aortic valve or non-calcified valves; Patient has a hypertrophic obstructive cardiomyopathy; Patients with clinically significant conduction abnormalities (clinically significant sinus bradycardia, sinus block or pauses, clinically significant atrioventricular (AV)-block >I) at screening and at time of IMD implantation; Patient with iliofemoral vessel characteristics that would preclude safe passage of the introducer (both sides), as analyzed by a core lab:; severe calcification,; severe tortuosity (> two 90-degree bends),; diameter < 6 mm, in patients with acceptable levels of calcification and acceptable levels of tortuosity; diameter < 5.5, in patients with no calcification and no significant tortuosity, OR; subject has had an aorto-femoral bypass; Patient has severe mitral regurgitation, severe aortic regurgitation or severe tricuspid regurgitation, moderate or severe mitral stenosis; Patient refuses blood transfusions; Patient is pregnant or breast feeding.