CT-based 3D Planning, Computer Navigation and Subsequent Migration Analysis in Total Hip Arthroplasty

Key facts

Who runs it
Region Skane
Where
Sweden1 site in 1 countryChoose a country to see its sites
Trial code
Status
Completed
People taking part
27 people enrolled
Started
1 Apr 2021
Ended
15 Dec 2024
Type of study
Interventional
Treatments tested
  • CT group
Record updated
25 June 2025

Who can take part

Age
40 years to 75 years
Sex
Women and men
Healthy volunteers
Cannot take part

The registry criteria, word for word

Show all 5 criteriaShow less

Who can take part

  • Primary or secondary hip osteoarthritis
  • Qualified for total hip arthroplasty surgery at the regional Hospital

Who cannot take part

  • Other cause for assessing the patient as ineligible (such as: serious medical comorbidity or active drug abuse)
  • BMI >35
  • Unable to comprehend the patient information

This trial has no sites in United States.

It has sites in one country. Choose a country to see its sites.

About the trial

What the trial wants to find out

The aim of this study is to evaluate a new technique that optimizes the prosthesis position for patients who undergo total hip arthroplasty surgery. Today, most surgeons take a regular X-ray (2D) to plan the surgery. In this study, patients will do a computed tomography (CT) before surgery, and with the use of the new system, the investigators will be able to make a more accurate plan when it comes to prosthetic placement and leg length adjustment in 3D. The software uses artificial intelligence (AI) to generate the information required for clinical conclusions automatically, and it enables surgeons to adapt to each unique case and anticipate situations during surgery. The system also helps the surgeon during operation with a navigation tool to place the implant in the pre-operatively planned position. It guides surgeons in real-time to place the implants accurately. To see whether the plan and navigation were correct, the investigators will do a new computed tomography after surgery to look at the achieved result.

Read full original descriptionShow less

In addition to planning and navigation, the same system can be used to measure the migration of the prosthesis in relation to the bone over time using AI by comparing multiple scans. The investigators aim to follow all patients for 2 years (total of 4 CT scans after surgery) with the intention to be able to foresee implant loosening.

The group in the trial

  • CT groupOther group

    CT-scan preoperatively, postoperatively and at 3 months, 1 and 2 years. Per-operative navigation based on the CT scan.

Data and sources

Registry record
Listed on ClinicalTrials.gov.
Official title
Evaluation of a Novel CT-based 3D Planning, Computer Navigation and Subsequent Migration Analysis in Total Hip Arthroplasty: A Single Arm Study With 2 Years Follow-up
Record updated
25 June 2025