Under construction – not a live service
Sign in
Taking peopleNo phase

VT Ablation in the iCMR

This trial has no sites in United States.

It has sites in 2 countries. Choose a country to see its sites.

Questions to ask the study team

  1. How often do I need to come in, and for how long each time?
  2. Are travel costs paid?
  3. Can I keep my own doctor?
  4. What happens if I want to stop?

Contact the study team: see the registry record → Contacts and Locations

Print a page for my doctor

Trial details

Who runs it
Imricor Medical Systems
Trial code
NCT05543798
Record updated
10 November 2026
Original description
The VISABL-VT is a prospective, single-arm, multi-center, interventional investigation of the safety and efficacy of radiofrequency (RF) ablation of ventricular tachycardia associated with ischemic cardiomyopathy performed with the Vision-MR Ablation Catheter 2.0 in the iCMR environment.Read full original descriptionShow less

Vision-MR Ablation Catheter 2.0 for the Treatment of Ventricular Tachycardia

The VISABL-VT is a prospective, single-arm, multi-center, interventional investigation of the safety and efficacy of radiofrequency (RF) ablation of ventricular tachycardia associated with ischemic cardiomyopathy performed with the Vision-MR Ablation Catheter 2.0 in the iCMR environment.

Inclusion: Roll-in subjects only: Documentation of premature ventricular contractions indicated for ablation therapy (subjects may or may not be diagnosed with Ischemic Cardiomyopathy); Documented (ECG/EGM) spontaneous episode of sustained ventricular tachycardia within 6 months of the procedure; Diagnosis of Ischemic Cardiomyopathy; AAD therapy refractory, contraindicated, not tolerated, or not desired; 18 years or older.

Exclusion: Previous cardiac surgery within 60 days of procedures; Patients who do not tolerate anticoagulation therapy; Previous intertribal septal patch or prosthetic atrial septal defect closure device; Myocardial infarction requiring stent implantation within 90 days of procedure; Known/uncontrolled stroke risks; Class IV Heart Failure; Allergy to contrast agents (e.g., Gadolinium); Active infection; Unstable angina; Ejection Fraction (EF) < 25%; Patients with a glomerular filtration rate (GFR) < 30; Implanted with non-MR compatible medical devices or contraindicated for an MRI; Presence of intracardiac thrombus (verified via CT/MRI/TEE/TTE within 48 hours of procedure - or at start of procedure); Thrombocytopenia or coagulopathy; Mechanical mitral and/or aortic valve precluding access to the left ventricle; Severe aortic stenosis; Women who are pregnant; Known or suspected myxoma; Life expectancy < 12 months; Enrollment in another study without sponsor approval.

ClinicalTrials.gov NCT05543798