Under construction – not a live service
Sign in
Active, not recruitingNo phase

Ankura™ TAA Stent Graft System Post-Market Clinical Follow-up Study

Key facts

Who runs it
Lifetech Scientific (Shenzhen) Co., Ltd.
Where
Germany, Greece, Italy, Russia, and Türkiye15 sites in 5 countriesChoose a country to see its sites
Trial code
Status
Active, not recruiting
People taking part
147 people enrolled
Started
3 May 2023
Expected to end
30 Dec 2030
Type of study
Observational
Treatments tested
  • Ankura™ TAA Stent Graft System
Record updated
26 May 2026

Who can take part

Age
18 years to 85 years
Sex
Women and men
Healthy volunteers
Cannot take part

The registry criteria, word for word

Show all 17 criteriaShow less

Who can take part

  • Patient has descending thoracic aortic aneurysm (DTA) or type B aortic dissection (TBAD), who needs endovascular repair (TEVAR)
  • Life expectancy > 1 year
  • Patient or legally authorized representative understands the nature of the clinical trial, agrees to its provisions, agrees to comply with the requirements of the study including a 3-year follow-up, and signed applicable Informed Consent Form
  • Patient's characteristics consistent with Ankura™ Stent Graft System IFU and sizing guidelines, which indicate as following:; For descending thoracic aortic aneurysm (DTA) patient:; Adequate iliac/femoral access vessel that is compatible with the required delivery system; Aortic inner diameter in the range of 18-42mm; ≥15mm non-aneurysmal aorta proximal and distal to the lesion; Morphology suitable for endovascular repair; For type B aortic dissection (TBAD) patient:; Adequate iliac/femoral access vessel that is compatible with the required delivery system; ≥15mm landing zone proximal to the primary entry tear; proximal extent of the landing zone must not be dissected. Diameter at proximal extent of proximal landing zone in the range of 16-44mm; ≥15mm landing zone distal to the primary entry tear; distal extent of the landing zone must not be dissected. Diameter at distal extent of distal landing zone in the range of 16-44mm; Morphology suitable for endovascular repair

Who cannot take part

  • Myocardial infarction or stroke within 3 months prior to the procedure
  • Participant in other drug or medical device clinical trials
  • Patient with any contraindications mentioned in the Ankura™ Stent Graft System IFU:; Patients with acute systemic infection; Patients who have had other devices implanted in the cardiovascular cavity, which will interfere with the placement of this device; Patients with mesenteric blood flow mainly supplied by the inferior mesenteric artery; Patients who have allergic reaction to the device; Patients who are not suitable for endovascular repair in vascular morphology; Patients who cannot tolerate contrast agents due to severe renal insufficiency; Patients who are allergic to contrast agents; Aneurysms neck with thrombus; Non-aneurysmal aortic proximal neck length <1.5cm; Non-aneurysmal aortic distal anchorage zone <1.5cm; For aneurysms, Non-aneurysmal aortic diameter <18mm or >42mm. For Type B dissections, Non-aneurysmal aortic diameter <16mm or >44mm
  • Patient with hereditary connective tissue disease, including but not limited to Marfan Syndrome or Ehlers-Danlos Syndrome
  • Patient with an unstable angina pectoris or hearth insufficiency New York Heart Association Functional Classification (NYHA) 3 or 4
  • Patient with access vessel which are to tortuous, narrow or any kind of reasons that would lead to failure of introduction and advancing an introducer sheath
  • Any condition (medical or anatomic) which makes the patient not suitable for endovascular repair according to the opinion of the investigator
  • Age<18 Years or Age> 85 Years
  • Patient with traumatic aortic injury
  • Patient with uncorrectable coagulopathy
  • Patient with morbid obesity, weight greater than 350 Pounds (150kg), or who cannot undergo accurate fluoroscopy examination due to obesity
  • Pregnant or plan to be pregnant or breast feeding
  • American Society of Anesthesiologists Physical Status Classification (ASA) classification 5 or higher

This trial has no sites in United States.

It has sites in 5 countries. Choose a country to see its sites.

About the trial

What the trial wants to find out

The purpose of this study is to collect clinical data on patient outcomes, evaluate the safety and performance of Ankura TAA Stent Graft System and Surpass Super Stiff Guidewire, and build clinical evidence for patients with Descending Thoracic Aneurysm (DTA) or Type B Aortic Dissection (TBAD).

The group in the trial

  • Patients with Descending Thoracic Aneurysm (DTA) or Type B Aortic Dissection (TBAD)

    All patients who signed informed consent and are used with Ankura™ TAA Stent Graft Systems will undergo follow-up (FU) evaluations as per local hospital standards and corresponding IFU which is expected to be at the following time points post-implant: Before discharge, 30days after the procudure, 3-6 months after the Procedure, 12 months after the procedure, 24 months after the procedure, 36 months after the procedure

    Treatment: Ankura™ TAA Stent Graft System

Data and sources

Registry record
Listed on ClinicalTrials.gov.
Official title
Ankura™ TAA Stent Graft System Post-Market Clinical Follow-up Study: Multi-center, Prospective, Observational, Post-Market Follow-up Study
Record updated
26 May 2026