Under construction – not a live service
Sign in
Taking people in United StatesNo phase

Tests an artificial heart device in adults with severe heart failure

Tests the BiVACOR artificial heart as temporary support for adults with severe heart failure.

Plain-language title generated from the registry record
Registry title: BiVACOR® Total Artificial Heart Early Feasibility Study

Key facts

Where
Cincinnati, Durham, Houston, and Phoenix, United StatesSee the 4 sites

Could this be for you?

Answer for yourself. This is not a decision: only the study team can say whether you can take part.

  • Are you between 18 and 70 years old?

Source: NCT06174103, who can take part

Where in United States

  • The Christ HospitalCincinnati, United StatesTaking people
  • Duke University HospitalDurham, United StatesTaking people
  • Texas Heart Institute / Baylor St. Luke's Medical CenterHouston, United StatesTaking people
  • Banner-University Medical Center PhoenixPhoenix, United StatesTaking people

Questions to ask the study team

  1. How often do I need to come in, and for how long each time?
  2. Are travel costs paid?
  3. Can I keep my own doctor?
  4. What happens if I want to stop?
Print a page for my doctor

Trial details

Who runs it
BiVACOR Inc.
Trial code
NCT06174103
Record updated
28 September 2026
Original description
The purpose of this study is to assess the feasibility of using the BiVACOR Total Artificial Heart (TAH) System to support adult patients with severe biventricular heart failure, or univentricular heart failure in which left ventricular assist device (LVAD) support is not recommended, who require mechanical circulatory support to sustain life. The BiVACOR TAH System is intended for use as a bridge to transplant (BTT). Feasibility will be assessed by evaluating safety and performance of the BiVACOR TAH System in study subjects.Read full original descriptionShow less

BiVACOR® Total Artificial Heart Early Feasibility Study

The purpose of this study is to assess the feasibility of using the BiVACOR Total Artificial Heart (TAH) System to support adult patients with severe biventricular heart failure, or univentricular heart failure in which left ventricular assist device (LVAD) support is not recommended, who require mechanical circulatory support to sustain life. The BiVACOR TAH System is intended for use as a bridge to transplant (BTT). Feasibility will be assessed by evaluating safety and performance of the BiVACOR TAH System in study subjects.

Inclusion: Patient has severe, irreversible biventricular heart failure and is eligible for biventricular mechanical circulatory support based on the International Society of Heart and Lung Transplantation (ISHLT) guidelines or has univentricular heart failure in which LVAD support is not recommended. ISHLT Guidelines for Biventricular Support:; Biventricular failure with at least two of the following hemodynamic and/or echocardiographic measurements; Right ventricular ejection fraction (RVEF) ≤ 30%; Right ventricular stroke work index (RVSWI) ≤ 0.25 g/m/beat/m2; Tricuspid annular plane systolic excursion (TAPSE) ≤ 14 mm; Right ventricular (RV) to left ventricular (LV) end-diastolic diameter ratio > 0.72; Central venous pressure (CVP) > 15mmHg; CVP to pulmonary capillary wedge pressure (PCWP) ratio > 0.63; Tricuspid insufficiency grade 4; Pulmonary artery pressure index (PAPi) < 2; Treatment-refractory recurrent and sustained ventricular tachycardia or ventricular fibrillation in the presence of untreatable arrhythmogenic pathologic substrate; Heart failure due to restrictive or constrictive physiology (e.g., hypertrophic cardiomyopathy, cardiac amyloidosis/senile or other infiltrative heart disease); Patient is categorized as INTERMACS Patient Profile Classification 2 or 3; Patient is classified as NYHA Class IV; Patient has a left ventricular ejection fraction (LVEF) ≤ 25%, with the exception of patients with restrictive or constrictive physiology; Patient is inotrope dependent, OR has a cardiac index (CI) ≤ 2.2 L/min/m2 without inotropes if inotropes are contraindicated (e.g., restrictive or constrictive heart failure), and meets one of the following criteria:; Is on optimal medical management (OMM), based on current heart failure practice guidelines for at least 45 out of the last 60 days and is failing to respond or is not able to tolerate OMM; or; Has advanced heart failure for at least 14 days and is dependent on an intra-aortic balloon pump (IABP) or similar temporary mechanical circulatory support device (MCSD) for at least seven days; Patient is eligible for cardiac transplantation as determined by the implanting center; Patient has adequate room in the chest as determined by 3-D imaging or other standard clinical assessments; Patient has read and understands the informed consent form (ICF) and has voluntarily provided informed consent.

Exclusion: Patient has contraindications to anticoagulation or antiplatelet therapies; Patient is highly pre-sensitized prior to pump implantation; Patient is on pre-implant extracorporeal membrane oxygenation (ECMO) for > 7 days; Patient is on pre-implant temporary MCSD for more than 21 days [e.g., Intra-aortic balloon pump (IABP), Impella, CentriMag, etc.] unless ambulatory and free from adverse effects associated with the MCSD; Patient has a current drug and/or alcohol addiction or known substance abuse; Patient has severe chronic obstructive pulmonary disease (COPD) or restrictive lung disease requiring home oxygen; Patient has primary pulmonary hypertension ≥ 8 Wood units; Patient has been diagnosed with severe cardiac cachexia or irreversible frailty; Patient has diabetes with advanced diabetic neuropathy with accompanying skin ulceration; Patient has a blood-borne infection within seven days of eligibility evaluation. Positive blood cultures reflective of contaminants (e.g., Staphylococcus epidermidis) will not be considered an exclusion; Patient has a co-morbidity or illness that would limit survival to less than two years; Patient has insufficient social support or a history of non-compliance with medical instructions as determined by the Investigator; Patient has coagulopathy defined by a platelet count < 50 k/µl; Patient has severe end-organ dysfunction as evidenced by:; Total bilirubin > 4.0 mg/dL or cirrhosis confirmed by imaging or positive biopsy, and/or; Glomerular filtration rate (GFR) < 30 mL/min/1.73 m2 or renal replacement therapy dependence; Patient has insufficient space in the chest to accommodate the BiVACOR pump; Patient has a body mass index (BMI) ≥ 35 kg/m2; Patient is unconscious and unresponsive; Patient is implanted with durable mechanical circulatory support (LVAD or RVAD); Patient experienced cerebrovascular accident (CVA) within three months of eligibility evaluation; Patient has severe systemic light-chain amyloidosis; Patient is pregnant or planning pregnancy; Patient is participating in another clinical trial that may impact or confound the results of the BiVACOR TAH EFS.

ClinicalTrials.gov NCT06174103