Sign in
CompletedNo phase

Electro-acupuncture for Irritable Bowel Syndrome With Constipation

Key facts

Who runs it
Nanyang Technological University
Where
Singapore1 site in 1 countryChoose a country to see its sites
Trial code
Status
Completed
People taking part
60 people enrolled
Started
12 Sept 2024
Ended
21 May 2026
Type of study
Interventional, 2 groupsOne group gets a sham (pretend) treatment, for comparison.
Treatments tested
  • Acupuncture needles
Record updated
26 May 2026

Who can take part

Age
21 years to 65 years
Sex
Women and men
Healthy volunteers
Can take part

The registry criteria, word for word

Show all 16 criteriaShow less

Who can take part

  • Fulfilment of the Rome IV criteria for IBS-C
  • Age of 21 to 65 years (inclusive)
  • Weekly average of worst daily abdominal pain score of ≥3 (0-10 scale) for at least 12 weeks before the first visit and during screening period
  • <3 complete spontaneous bowel movements (CSBMs) per week for at least 12 weeks before the first visit and during screening period
  • Written informed consent

Who cannot take part

  • Appendectomy or cholecystectomy within the past 2 months, or other abdominal surgeries within the past 6 months prior to trial enrollment
  • Patients who have received acupuncture treatment in last three months, or took concomitant medication with affect gastrointestinal motility or visceral sensation, such as antidiarrheal agent, antidepressant, narcotic analgesic, and anticholinergic
  • Alcoholism or drug abuse in past 1 year
  • Antibiotics and probiotics/prebiotics usage in the previous month
  • Medical history of inflammatory bowel diseases, carbohydrate malabsorption, hormonal disorder, known allergies to food additives, and/or any other serious diseases
  • History of gastrointestinal tract segment removal or bariatric surgery for obesity
  • Unstable medical conditions that could be associated with abdominal pain or discomfort and could potentially influence the assessments in this trial (e.g., chronic kidney disease, endometriosis, lactose intolerance)
  • Diagnosed with primary severe mental illness
  • Having needle phobia or allergy to acupuncture needle materials
  • Pregnancy or breast-feeding
  • Participating in other clinical studies

This trial has no sites in United States.

It has sites in one country. Choose a country to see its sites.

About the trial

What the trial wants to find out

The aim of the clinical trial is to evaluate the efficacy and safety of electro-acupuncture for irritable bowel syndrome with constipation (IBS-C) patients. 60 IBS-C patients will be randomized and allocated to either the electro-acupuncture arm or the sham acupuncture arm. We hypothesize that electro-acupuncture would result in superior symptom improvement compared to sham acupuncture. In addition, biological samples (blood, urine, and stool) will be collected during the trial for future exploratory studies. These samples will be used to investigate changes in gut microbiota composition and related metabolites. These analyses aim to explore potential mechanistic links between electro-acupuncture interventions and clinical outcomes in subsequent research. Apart from the IBS-C participants, 30 healthy volunteers aged 21 to 65 years (inclusive) will be recruited to provide blood, urine, and stool samples. These samples will serve as a reference for comparative analyses with those from IBS-C patients before and after electro-acupuncture treatment. The healthy controls will not receive any interventions.

The 2 groups in the trial

  • Electro-Acupuncture groupTreatment being tested

    Disposable acupuncture needles (0.30 mm in diameter and 25-40 mm in length) are inserted at a depth of 10-30 mm obliquely into scalp acupuncture points (Baihui, Toulinqi) or straightly into body acupuncture points (Taichong, Zhangmen, Sanyinjiao, Zhongwan, Guanyuan, Tianshu, Zusanli). Electroacupuncture will be applied to the abdominal points at fast and dispersed waves through electric needle stimulator (ES-160 6-Channel Programmable Electro-acupuncture) for 30 min. The intensity is adjusted to a level at which patients feel comfortable. The alternating stimulation is believed to produce maximal biochemical responses in the brain.

    Treatment: Acupuncture needles

  • Sham-Acupuncture groupSham treatment, for comparison

    Disposable acupuncture needles (0.30 mm in diameter and 25-40 mm in length) are inserted (actual penetration of the skin) at the same way as in the acupuncture group but on sham-acupuncture points (Sham-Baihui, Sham-Toulinqi, Sham-Taichong, Sham-Zhangmen, Sham-Sanyinjiao, Sham-Zhongwan, Sham-Guanyuan, Sham-Tianshu, Sham-Zusanli. The sham points aren't acupuncture points nor located on meridians. Both the electroacupuncture and sham acupuncture groups follow the same procedures, including connection to the stimulator device for the same duration. In the sham group, although no electrical current is delivered, the power switch is turned on and the knobs are manipulated to produce audible clicking sounds, mimicking auditory cues of active treatment.

    Treatment: Acupuncture needles

Data and sources

Registry record
Listed on ClinicalTrials.gov.How to verify a trial in the registry
Official title
Electro-acupuncture for Irritable Bowel Syndrome With Constipation: a Pilot, Randomized, Double-blinded, Sham-controlled Trial
Publications
Record updated
26 May 2026