Under construction – not a live service
Sign in
Taking people in SwedenNo phase

Heart function monitored during robotic surgery in head-down position

Studies heart performance in people with heart failure during robotic surgery in head-down tilt.

Plain-language title generated from the registry record
Registry title: Cardiac Performance During Steep Trendelenburg Position in Patients Undergoing Robotic Surgery Surgery.

Key facts

Where
Karlstad, SwedenSee the site

Where in Sweden

  • Dpt of Anesthesiology&Intensive Care; Central Hospital of KarlstadKarlstad, SwedenTaking people

Questions to ask the study team

  1. How often do I need to come in, and for how long each time?
  2. Are travel costs paid?
  3. Can I keep my own doctor?
  4. What happens if I want to stop?
Print a page for my doctor

Trial details

Who runs it
Karlstad Central Hospital
Trial code
NCT06336746
Record updated
12 February 2026
Original description
The field of robotic-assisted laparoscopic surgery increases all the time. Older and more fragile patients which are not suitable for major open surgery could be scheduled for robotic- assisted surgery. The peroperative anesthesiological challenges and stresses during this type of surgery could anyway be even more prominent.Read full original descriptionShow less

Effects of Steep Trendelenburg and Pneumoperitoneum on Cardiac Performance During Robotic-assisted Surgery in Patients With Normal and Low Ejection Fraction.

The field of robotic-assisted laparoscopic surgery increases all the time. Older and more fragile patients which are not suitable for major open surgery could be scheduled for robotic- assisted surgery. The peroperative anesthesiological challenges and stresses during this type of surgery could anyway be even more prominent.

The extreme positioning of patients during robotic surgery in the pelvis, often 30 degrees head down tilting (Trendelenburg positioning), should increase the work load of the heart significantly. There are no studies concerning fragile patients with heart failure during these conditions.

In this study the circulatory effects in patients with normal heart function and preexisting heart failure will be studied during robotic surgery in extreme Trendelenburg positioning

During surgery the work load and performance of the heart will be monitored using an esophageal doppler and optical spectrophotometry measuring regional saturation of the brain. This study can identify patients at risk of developing critical circulatory failure during this type of surgery.

Inclusion: Consecutive Patients Scheduled for Robotic Surgery with Trendelenburg positioning; -.

Exclusion: Dementia,; Age <18; Not able to give written consent -.

ClinicalTrials.gov NCT06336746