INFLATE Study: Investigation of the Safety and Performance of a Novel PTV Balloon in Patients Undergoing TAVI for Severe Aortic Stenosis
This trial has no sites in United States.
It has sites in one country. Choose a country to see its sites.
Questions to ask the study team
- How often do I need to come in, and for how long each time?
- Are travel costs paid?
- Can I keep my own doctor?
- What happens if I want to stop?
Contact the study team: see the registry record → Contacts and Locations
Print a page for my doctorTrial details
- Who runs it
- Biosensors Europe SA
- Trial code
- NCT06816485
- Record updated
- 16 April 2026
- Original description
This clinical investigation is being done to evaluate the safety and effectiveness of a new device, a PTV Balloon, that will be used to open up an area in the heart (the valve) before and potentially after placing a new valve in patients requiring a new heart valve.Read full original descriptionShow less
Investigation of the Safety and Performance of a Novel PTV Balloon in Patients Undergoing TAVI for Severe Aortic Stenosis
This clinical investigation is being done to evaluate the safety and effectiveness of a new device, a PTV Balloon, that will be used to open up an area in the heart (the valve) before and potentially after placing a new valve in patients requiring a new heart valve.
The main question it aims to answer is:
What percentage of patients develop new heart conduction problems after using the investigational PTV Balloon for pre-dilatation?
Participants will:
1. Undergo a TAVI procedure, where the PTV Balloon will be used for pre-dilatation and may also be used for post-dilatation. 2. Will be followed up until discharge or up to 7 days, whichever happens first.
Inclusion: Symptomatic severe calcific stenosis of a native aortic valve with an AVA ≤1.0 cm2 (or AVA index ≤0.6 cm2/m2) AND mean aortic pressure gradient ≥ 40mmHg OR maximal transaortic velocity ≥4.0m/s OR Doppler velocity index ≤0.25 on site-reported echocardiography; Local multi-disciplinary Heart Team agrees on indication and eligibility for TAVI; Age ≥18 years; Patient has signed the Patient Informed Consent Form; Patient is willing and able to comply with requirements of the study; Patients planned for trans-femoral procedure.
Exclusion: Acute MI ≤30 days prior to the index procedure; Cerebrovascular accident (CVA) or transient ischemic attack (TIA) ≤6 months or prior CVA with moderate or severe disability (e.g. modified Rankin scale score >2); Currently participating in another investigational drug or device study; Significant disease of the aorta that would preclude safe advancement of the TAVI system; Severe ilio-femoral vessel disease that would preclude safe performance of the TAVI procedure; Severe tricuspid regurgitation and/or failing right heart (site-reported); Evidence of active endocarditis or other acute infections; Renal failure requiring continuous renal replacement therapy; Untreated clinically significant coronary artery disease requiring revascularization; Symptomatic carotid or vertebral artery disease requiring intervention or carotid/vertebral intervention within the preceding 45 days; Severe (greater than 3+) mitral insufficiency (site-reported); Isolated Aortic Insufficiency; Severe left ventricular dysfunction with ejection fraction (EF) <20% (site-reported); History of bleeding diathesis or coagulopathy; acute blood dyscrasias as defined: thrombocytopenia (platelets <80,000/µl), acute anemia (hemoglobin <10 g/dl), leukopenia (WBC <3000/ µl); Known hypersensitivity to contrast media, which cannot be adequately pre-medicated or contraindication to anticoagulant or anti-platelet medication or to nitinol alloy or to bovine tissue; Mean aortic annulus diameter as measured by pre-procedural CT or internal diameter of the bioprosthesis is <16 mm or >30 mm; Echocardiographic evidence of intracardiac thrombus, mass or vegetation (site-reported); Pregnancy or intend to become pregnant during study participation; Unicuspid aortic valve; Non-calcified aortic stenosis; Identified high risk of coronary occlusion due to Sinus of Valsalva anatomy and/or bulky calcified aortic valve leaflets in close proximity to coronary ostia; Patients with a permanent pacemaker; Patients with pre-existing LBBB, RBBB and AV block 2 and 3.