Tests a glucose sensor device in older adults with type 2 diabetes
Tests continuous glucose monitoring in older adults with type 2 diabetes not using insulin.
Plain-language title generated from the registry record
Registry title: Effect of Continuous Glucose Monitoring System on Glycemic Control in Non-insulin-Treated Elderly People With Type 2 Diabetes
Key facts
- Where
- Shenzhen, ChinaSee the 21 sites
Where in China
- Guantian Community Health Service StationShenzhen, ChinaTaking people
- Huiyu Mingdu Community Health Service StationShenzhen, ChinaTaking people
- Langxin Community Health Service StationShenzhen, ChinaTaking people
- Luozu Community Health Service CenterShenzhen, ChinaTaking people
- Shenzhen Buxin Community Health Service CenterShenzhen, ChinaTaking people
- Shenzhen Dalang Community Health Service CenterShenzhen, ChinaTaking people
- Shenzhen Fifth Avenue Health Service StationShenzhen, ChinaTaking people
- Shenzhen Haifu Health Service StationShenzhen, ChinaTaking people
- Shenzhen Haihua Community Health Service CenterShenzhen, ChinaTaking people
- Shenzhen Haile Community Health Service StationShenzhen, ChinaTaking people
- Shenzhen Haile Huafu Health Service StationShenzhen, ChinaTaking people
- Shenzhen Haiyu Health Service StationShenzhen, ChinaTaking people
- Shenzhen Jiaan Health Service StationShenzhen, ChinaTaking people
- Shenzhen Jiangangshan Health Service CenterShenzhen, ChinaTaking people
- Shenzhen Jiari Mingju Health Service StationShenzhen, ChinaTaking people
- Shenzhen Pingzhou Community Health Service CenterShenzhen, ChinaTaking people
- Shenzhen Xinan Lake Health Service StationShenzhen, ChinaTaking people
- Shenzhen Xingdong Health Service StationShenzhen, ChinaTaking people
- Shenzhen Zhongliang Chuangxin Health Service StationShenzhen, ChinaTaking people
- Shuitian Health Service CenterShenzhen, ChinaTaking people
- Tianbao Community Health Service CenterShenzhen, ChinaTaking people
Questions to ask the study team
- How often do I need to come in, and for how long each time?
- Are travel costs paid?
- Can I keep my own doctor?
- What happens if I want to stop?
Trial details
- Who runs it
- Shanghai 6th People's Hospital
- Trial code
- NCT07007676
- Record updated
- 8 September 2026
- Original description
The goal of this clinical trial is to learn if continuous glucose monitoring system works to improve glucose control in non-insulin-treated older adults with type 2 diabetes. The main questions it aims to answer are:Read full original descriptionShow less
Effect of contINuous Glucose moniToring System on glycEmic controL in Non-insuLin-Treated Elderly People With Type 2 Diabetes: a Randomized Controlled Trial
The goal of this clinical trial is to learn if continuous glucose monitoring system works to improve glucose control in non-insulin-treated older adults with type 2 diabetes. The main questions it aims to answer are:
* Dose the use of continuous glucose monitoring system improve glucose control in older adults with type 2 diabetes treated with oral antidiabetic drugs only? * Dose the use of continuous glucose monitoring system affect psychological outcomes in older adults with type 2 diabetes treated with oral antidiabetic drugs only? Researchers will compare continuous glucose monitoring to standard blood glucose monitoring to see if continuous glucose monitoring works better in glucose management.
Participants will:
* Wear continuous glucose monitoring every 2 months or standard blood glucose monitoring for 6 months * Visit the clinic once every 2 months for follow-up * Keep a diary of their blood glucose when continuous glucose monitoring was not used
Inclusion: Age ≥ 60 years at the time of screening; Diagnosed with type 2 diabetes mellitus; Treated with two or more oral antidiabetic drugs with a stable medication regimen (medication classes) during the 3 months prior to entry; Suboptimal glycemic control, defined as HbA1c ≥ 7.5% and ≤ 10% at screening or within 30 days prior to screening visit; Has a smart phone compatible with CGM and BGM systems; Willing and able to provide written informed consent; At least 240 hours (10 out of 14 days) of sensor glucose data from the blinded CGM pre-randomization phase.
Exclusion: Use of insulin or Glucagon-Like Peptide-1 (GLP-1) receptor agonists within 3 months prior to screening; Use of any CGM device within 3 months prior to screening; Planned surgery or other procedures within the next 6 months that may interfere with scheduled follow-up visits; Participation in any other clinical trial within 3 month prior to screening, or concurrently enrolled, or planning to participate in another trial during the study period; Participants were unable to tolerate tape adhesive around sensor placement area, or with medically documented allergy towards the adhesive (glue) of plasters, or with serious skin diseases (e.g. psoriasis vulgaris, bacterial skin diseases) around sensor placement area; Considered unsuitable for participation by the investigators, including but not limited to individuals with dementia, psychiatric disorders, extreme visual or hearing impairment that would impair ability to use real-time CGM assessed; Estimated glomerular filtration rate (eGFR) < 30 ml/min/1.73m2; Current or anticipated acute uses of glucocorticoids (oral, injectable, or IV), that will affect glycemic control.