Testing an automatic insulin pump in adults with diabetes and slow stomach emptying
Tests an automatic insulin pump in adults with type 1 diabetes and slow stomach emptying.
Key facts
- Who runs it
- Viral N. Shah
- Where
- Indianapolis, United StatesSee the site
- Trial code
- Registry title
- To Study the Efficacy and Safety of Medtronic 780G Insulin Pump in People With Gastroparesis and Type 1 Diabetes.
- Status
- Recruiting
- People taking part
- 34 people, planned
- Started
- 9 Feb 2026
- Expected to end
- 1 Apr 2027
- Type of study
- Interventional, 2 groupsOne group gets no study treatment, for comparison.
- Treatments tested
- Medtronic 780G AID
- Record updated
- 10 November 2026
Who can take part
AI summary
From the trial's eligibility criteria. Machine-read from the registry text on this page, so it can be wrong. The registry text below and the trial team decide who can take part.
The trial is looking for adults with type 1 diabetes and gastroparesis (slow stomach emptying) to test the Medtronic 780G automated insulin pump.
- Age
- 18 years or older
- Sex
- All sexes can join
- Disease stage
- Type 1 diabetes for at least 12 months, with a stable insulin plan for at least 2 months. HbA1c of 8.0% (64 mmol/mol) or higher. Gastroparesis diagnosed by the National Institute of Health (NIH) definition.
- Earlier treatment
- Must have a stable insulin plan for at least 2 months. Must be willing to use the Medtronic 780G system with the Simplera CGM. If in the usual care group and already on a pump, must use it in manual mode only.
- Biomarker or test result
- HbA1c of 8.0% (64 mmol/mol) or higher
Main reasons for not taking part
- Pregnancy, breastfeeding, or wanting to become pregnant
- Using inhaled insulin (Afrezza) or any glucose-lowering medicine other than insulin
- Kidney function eGFR below 30, or on dialysis
- Severe low blood sugar in the past 3 months, or 2 or more hospital stays for DKA in the past 12 months
- Steroid medicine for 2 weeks or more, or history of stomach outlet blockage or other structural stomach and gut problems
The registry criteria, word for word
Show all 19 criteriaShow less
Who can take part
- Age ≥18 years
- Diagnosis of T1D for at least 12 months with stable insulin regimen for at least 2 months
- HbA1c ≥8.0%
- Diagnosis of gastroparesis per National Institute of Health (NIH) definition
- Willing to use Medtronic 780G system either with Simplera CGM
- Ability to provide informed consent before any trial-related activities
- If randomized to usual care group and on an insulin pump already, should be willing to use pump in manual mode only for the duration of the study
Who cannot take part
- Current use (≥ 2 weeks of continuous use) of any steroidal medication, or anticipated long-term steroidal treatment (>4 weeks continuously), during the study period
- History of SH in the previous 3 months
- Use of investigational drugs within 5 half-lives prior to screening
- History of gastric outlet obstruction or other gastrointestinal structural abnormalities
- History of two or more episodes DKA requiring hospitalization in the past 12 months
- Any medical (such as severe cardiovascular disease, malignancy, chronic liver disease) or psychosocial conditions that make a person unfit for the study at the discretion of investigators
- Current use of cannabis or history of cannabinoid hyperemesis syndrome
- Patients with T1D using any glucose lowering medications other than insulin at the time of screening
- Estimated glomerular filtration rate (eGFR) <30 or on dialysis
- Age <18 years
- Current use of inhaled insulin (Afrezza)
- Pregnancy, breast feeding, or wanting to become pregnant
Where in United States
- Indiana University Health, Univeristy hospitalIndianapolis, United StatesContact: Zunera Tariq, MDTaking people
About the trial
What the trial wants to find out
The goal of this clinical trial is to evaluate the efficacy and safety of Medtronic 780G automated insulin delivery system in adult persons with type 1 diabetes and gastroparesis.
The 2 groups in the trial
- Medtronic 780G groupTreatment being tested
Treatment: Medtronic 780G AID
- Usual careNo study treatment, for comparison
Participants will continue either multiple daily injections or non-AID insulin pumps
Questions to ask the study team
- How often do I need to come in, and for how long each time?
- Are travel costs paid?
- Can I keep my own doctor?
- What happens if I want to stop?
Contact the study team: see the registry record → Contacts and Locations
Print a page for my doctorData and sources
- Registry record
- Listed on ClinicalTrials.gov.
- Official title
- Efficacy and Safety of Medtronic 780G Automated Insulin Delivery System in Adults With Type 1 Diabetes and Gastroparesis
- Plain-language title
- Testing an automatic insulin pump in adults with diabetes and slow stomach emptyingGenerated from the registry record. The registry title is the official one.
- AI summary
- From the trial's eligibility criteria. Read by machine on 12 November 2026.
- Record updated
- 10 November 2026