Under construction – not a live service
Sign in
Taking people in South KoreaNo phase

Early rhythm control treatment for hidden atrial fibrillation found by heart devices

Tests early rhythm control treatment against usual care in adults with device-detected atrial fibrillation.

Plain-language title generated from the registry record
Registry title: Efficacy of Early Rhythm Control Therapy in Patients With Subclinical Atrial Fibrillation

Key facts

Where
Seoul, South KoreaSee the site

Where in South Korea

  • Samsung Medical CenterSeoul, South KoreaTaking people

Questions to ask the study team

  1. How often do I need to come in, and for how long each time?
  2. Are travel costs paid?
  3. Can I keep my own doctor?
  4. What happens if I want to stop?
Print a page for my doctor

Trial details

Who runs it
Samsung Medical Center
Trial code
NCT07447297
Record updated
3 March 2026
Original description
The goal of this study to find out the efficacy of early rhythm therapy in patients with subclinical atrial fibrillation detected by Cardiac Electronic Implantable Devices.Read full original descriptionShow less

Efficacy of Early Rhythm Control Therapy in Patients With Subclinical Atrial Fibrillation

The goal of this study to find out the efficacy of early rhythm therapy in patients with subclinical atrial fibrillation detected by Cardiac Electronic Implantable Devices.

Early rhythm therapy includes antiarrhythmic drug, cardioversion, and catheter ablation. The general control group receives general management without the above atrial fibrillation rhythm control treatment.

Researchers will compare early rhythm control groups to general control groups to see if early rhythm therapy works to reduce the atrial fibrillation burden by 50% or more, or decrease the incidence of clinical AF documentation.

Participants will:

* Randomly allocated to two groups at a 1:1 ratio. * Receive the treatment according to their assigned group. * Visit the clinic once every three months for checkups and tests.

Inclusion: Among patients with Cardiac implantable electronic device (CIED), subjects with atrial high rate episodes found Cardiac implantable electronic devices: implantable loop recorder, pacemaker, implantable cardioverter defibrillator(ICD), cardiac resynchronized therapy(CRT); Patients aged 19 or older who have agreed to the study (if voluntary consent is deemed difficult, consent from legal representatives is obtained together); If the accumulated period of the atrial high rate episode during the three-month observation period is more than 21 hours; Patients whose atrial fibrillation has not been confirmed by electrocardiogram or holter monitoring within the past year from the time atrial high rate episode was detected; However, enrollment is possible even if it includes one of the following two cases ⓐ Patients diagnosed and recorded as atrial fibrillation on medical records but not confirmed by electrocardiogram or holter monitoring; ⓑ If there is a record of atrial fibrillation, but Paroxysmal AF less than 30 seconds.

Exclusion: Patients diagnosed with atrial fibrillation with 12-lead electrocardiogram or holter within the past year prior to participation in the study; Patients taking Class Ic, III of antiarrhythmic drugs prior to study participation; Patients whose life expectancy is less than one year (e.g., patients who can't even have a heart transplant, patients who receive DNR, Patients in hospice wards who refuse life-sustaining treatment, terminal cancer patients who cannot receive radiation or chemotherapy, etc.); Patients deemed inappropriate to participate in the study by the investigator; Patients who have had rhythm control treatments such as Radiofequency catheter ablation (RFCA), Total thoracoscopic ablation (TTA), Maze procedure (MAZEop), and antiarrhythmic treatment due to atrial fibrillation (except for CTI ablation with AFL).

ClinicalTrials.gov NCT07447297