Under construction – not a live service
Sign in
Not yet taking people in ChinaNo phase

A Prospective, Multicenter, Observational Study Evaluating Safety and Effectiveness of SAPIEN 3 Transcatheter Aortic Valve Replacement for Type-0 Bicuspid Aortic Valve Stenosis Patients in China

Key facts

Where
Beijing, ChinaSee the site

Where in China

  • Chinese Academy of Medical Sciences, Fuwai Hospital, BeijingBeijing, ChinaContact: Xiangbin Pan, MD.PhDNo longer taking part

Questions to ask the study team

  1. How often do I need to come in, and for how long each time?
  2. Are travel costs paid?
  3. Can I keep my own doctor?
  4. What happens if I want to stop?

Contact the study team: see the registry record → Contacts and Locations

Print a page for my doctor

Trial details

Who runs it
Chinese Academy of Medical Sciences, Fuwai Hospital
Trial code
NCT07450196
Record updated
7 May 2026
Original description
In China, bicuspid aortic valve (BAV) represents a significantly high proportion of the transcatheter aortic valve replacement (TAVR) population. The application of TAVR in patients with BAV is challenging due to complex anatomy. To date, no prospective study has evaluated the Sapien 3 TAVR in patients with Type-0 BAV.Read full original descriptionShow less

In China, bicuspid aortic valve (BAV) represents a significantly high proportion of the transcatheter aortic valve replacement (TAVR) population. The application of TAVR in patients with BAV is challenging due to complex anatomy. To date, no prospective study has evaluated the Sapien 3 TAVR in patients with Type-0 BAV.

Inclusion: Age ≥50 years, and after thorough physician-patient discussion and shared decision-making, willing to undergo or accept TAVR; Severe AS, defined as follows:; For symptomatic patients: i) Aortic valve area ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2), OR mean gradient ≥40 mm Hg, OR Maximal aortic valve velocity ≥4.0 m/sec by transthoracic echocardiography at rest b) For asymptomatic patients: i) Very severe AS with an aortic valve area of ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2), AND maximal aortic velocity ≥5.0 m/sec, or mean gradient ≥60 mm Hg by transthoracic echocardiography at rest, OR ii) Aortic valve area of ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2), AND a mean gradient ≥40 mm Hg or maximal aortic valve velocity ≥4.0 m/sec by transthoracic echocardiography at rest, AND an exercise tolerance test that demonstrates a limited exercise capacity, abnormal BP response, or arrhythmia OR iii) Aortic valve area of ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2), AND mean gradient ≥40 mmHg, or maximal aortic valve velocity ≥4.0 m/sec by transthoracic echocardiography at rest, AND a left ventricular ejection fraction <50%; Type-0 bicuspid aortic valve anatomy confirmed by multi-detector computed tomography (MDCT); The subject and the treating physician agree that the subject will return for all required post-procedure follow-up visits; Adequate iliofemoral access and acceptable level of vessel calcification and tortuosity for safe device implant; The study patient has provided written informed consent.

Exclusion: Emergency interventional/surgical procedures within 30 days of the valve implant procedure; Renal replacement therapy at the time of screening; Currently participating in an investigational drug or another device study. Note: Trials requiring extended follow-up for products that were investigational, but have since become commercially available, are not considered investigational trials. Observational studies are not considered exclusionary; Need for open heart surgery (including severe aortic regurgitation, mitral regurgitation or stenosis, or tricuspid regurgitation, congenital heart disease, AF, complex coronary artery disease); Hemodynamic or respiratory instability requiring inotropic support, mechanical ventilation or mechanical heart assistance within 30 days of the screening visit; Cardiac imaging (echo, CT, and/or MRI) evidence of ventricular mass, thrombus or vegetation; Ventricular dysfunction with LVEF < 30%; Challenging calcification based on physician's experience and discretion; Aortic valve is a congenital unicuspid valve, congenital Type-1 or Type-2 bicuspid valve, tricuspid or quadricuspid valve; Severe femoral, iliac or aortic atherosclerosis, calcification, coarctation, aneurysm or tortuosity, which prevents transfemoral TAVR; Pre-existing mechanical or bioprosthetic valve in any position; Hypertrophic cardiomyopathy with obstruction; Estimated life expectancy < 12 months.

ClinicalTrials.gov NCT07450196