Under construction – not a live service
Sign in
Taking people in ChinaNo phase

CorVad heart pump system for severe right-sided heart failure

Tests a catheter heart pump in adults with right heart failure.

Plain-language title generated from the registry record
Registry title: Safety and Feasibility of the CorVad Percutaneous Ventricular Assist System in Refractory Right Heart Failure

Key facts

Where
Beijing and Hefei, ChinaSee the 2 sites

Where in China

  • Beijing Anzhen Hospital, Capital Medical UniversityBeijing, ChinaTaking people
  • The First Affiliated Hospital of Anhui Medical UniversityHefei, ChinaNot yet recruiting

Questions to ask the study team

  1. How often do I need to come in, and for how long each time?
  2. Are travel costs paid?
  3. Can I keep my own doctor?
  4. What happens if I want to stop?
Print a page for my doctor

Trial details

Who runs it
Shenzhen Core Medical Technology CO.,LTD.
Trial code
NCT07704424
Record updated
15 July 2026
Original description
The goal of this clinical trial is to evaluate the safety and feasibility of the CorVad Percutaneous Ventricular Assist System (Device model: CorVad RS) in patients with right heart failure who continue to experience hemodynamic instability despite best medical therapy.Read full original descriptionShow less

Safety and Feasibility of the CorVad Percutaneous Ventricular Assist System in Refractory Right Heart Failure

The goal of this clinical trial is to evaluate the safety and feasibility of the CorVad Percutaneous Ventricular Assist System (Device model: CorVad RS) in patients with right heart failure who continue to experience hemodynamic instability despite best medical therapy.

Inclusion: Patients who develop refractory right heart failure within 48 hours after left ventricular assist device (LVAD) implantation, myocardial infarction, heart transplantation, or open-heart surgery, defined as:; despite ongoing treatment with oral heart failure medications, including continuous infusion of high-dose inotropic agents and/or vasopressors, and/or the use of more than one inotropic agent and/or vasopressor, the cardiac index (CI) remains less than 2.2 L/min/m²; and meets any one of the following criteria: 1) CVP > 15 mmHg; or, 2) CVP/pulmonary capillary wedge pressure (PCWP) or CVP/left atrial pressure (LAP) > 0.63; or, 3) echocardiographic evidence of moderate-to-severe right ventricular dysfunction meeting one of the following criteria: right ventricular basal diameter > 42 mm, right ventricular short-axis (or mid-chamber) diameter > 35 mm, tricuspid annular systolic excursion (TAPSE) score < 14 mm, right ventricular fractional area change (FAC) < 30%, tricuspid annular systolic peak velocity (TDI S') < 9 cm/s, and right ventricular free wall longitudinal strain > -20%; ≥ 18 years old; The patient or the patient's legal representative agrees to sign the informed consent form.

Exclusion: INTERMACS Stage 1 is defined as: despite the use of inotropic agents (positive inotropic drugs) and/or temporary mechanical support (such as IABP or ECMO), the patient remains hypotensive and shows signs of inadequate perfusion of vital organs (such as oliguria or worsening liver function), requiring immediate initiation of mechanical circulatory support to survive; For patients who have undergone LVAD implantation, acute neurological injury occurring after implantation, including stroke, hypoxic encephalopathy, or acute neurological deficits (such as seizures or altered levels of consciousness); Acute myocardial infarction with mechanical complications, including ventricular septal defect, cardiac rupture, or papillary muscle rupture; History of mechanical valve replacement of the tricuspid or pulmonary valve; Severe pulmonary hypertension, defined as a pulmonary artery systolic pressure > 60 mmHg; History of pulmonary artery graft replacement (artificial vessel); Current use of a right heart assist device or extracorporeal membrane oxygenation (ECMO) device; Thrombosis of the internal jugular vein and deep veins of the lower extremities, and/or the presence of a vena cava filter; Anatomical conditions that interfere with pump implantation or the safe use of the device, such as aortic dissection, Marfan syndrome, Erdheim-Chirlow disease (i.e., idiopathic medial necrosis, commonly associated with aortic dissection), etc; Congenital heart disease that precludes device implantation, or an unrepairated atrial septal defect or patent foramen ovale; Allergy or intolerance to contrast agents, or intolerance to anticoagulant or antiplatelet therapy; History of thrombolytic therapy within the past 30 days, known coagulation disorders, or hematologic disorders causing blood cell fragility or hemolysis; Severe hepatic or renal dysfunction, defined as total bilirubin ≥ 5 mg/dL or creatinine ≥ 4 mg/dL within 24 hours prior to treatment with the investigational device; Active infection, meeting at least two of the following criteria: white blood cell count > 12,500/μL, positive blood culture, or fever; Failed revascularization (for patients requiring right coronary revascularization), defined as a TIMI blood flow grade of 0 or 1 following percutaneous coronary intervention or coronary artery bypass grafting; Thrombus in the right atrium, right ventricle, and/or pulmonary artery; Severe tricuspid stenosis or regurgitation; Severe pulmonary valve stenosis or regurgitation; Current diagnosis of pulmonary embolism; Female patients who are pregnant or breastfeeding; Participation in any other clinical trial that may confound the study results or affect the study outcomes; Other circumstances deemed by the investigator to be incompatible with inclusion in this study.

ClinicalTrials.gov NCT07704424