Portico Valve-in-Valve Retrospective Registry
Retrospective Assessment of the Portico Transcatheter Aortic Valve for Valve-in-Valve Use
Forrás: ClinicalTrials.gov · Utoljára frissítve: 2025. febr. 28.
Rövid összefoglaló (regiszter, angolul)
The objective of this data-collection study is to retrospectively evaluate the safety and clinical performance of the Portico transthoracic aortic valve for Valve-in-Valve treatment of a failed aortic surgical bioprosthetic valve in patients who are considered at increased surgical risk for a redo surgical aortic valve replacement.
- Állapot (regiszter)
- Befejeződött
- Vizsgálattípus
- Megfigyeléses
- Résztvevők száma
- 71 (tényleges)
- Első benyújtás
- 2021. júl. 27.
- Kezdés
- 2021. okt. 21.
- Elsődleges befejezés
- 2023. dec. 29.
- Fő szponzor
- Abbott Medical Devices
- NCT-szám
- NCT05002088
Mit vállalsz
- Vizsgálat típusa: Megfigyeléses
- Bevont résztvevők: 71
- 2021. okt. 21. és az elsődleges befejezés (2023. dec. 29.) között
- 7 helyszín, 4 országban
- Vizitek és vizsgálatok: kérdezd a vizsgálat csapatát, a regiszter nem sorolja fel őket
A(z) ClinicalTrials.gov regisztermezőiből összeállítva. A vizsgálat felépítését írja le.
Ki nem vehet részt
Szó szerint a(z) ClinicalTrials.gov forrásból, témák szerint csoportosítva. Hogy ki vehet részt, azt csak a vizsgálat csapata dönti el.
Korábbi kezelés
- Subject had evidence of an acute MI, percutaneous intervention, or a peripheral intervention ≤30 days prior to Portico ViV index procedure (MI defined as: ST Segment Elevation as evidenced on 12 Lead ECG).
- Subject had an active peptic ulcer or has/had upper gastrointestinal (GI) bleeding ≤3 months prior to ViV index procedure.
- Subject had a documented history of a cerebrovascular accident (CVA) or a transient ischemic attack (TIA) ≤6 months prior to index procedure.
- Subject had active bacterial endocarditis or ongoing sepsis ≤ 6 months prior to the index procedure.
- Surgical aortic bioprosthetic valve was unstable or rocking.
- Subject was unable to tolerate antiplatelet or anticoagulant therapy
Más betegség
- Subject was considered hemodynamically unstable at the time of the ViV procedure (requiring inotropic support or mechanical heart assistance)
- Subject had a vascular condition (i.e. stenosis, tortuosity, or severe calcification) that made insertion and endovascular access to the aortic valve impossible.
Laborértékek
- Subject had uncontrolled blood dyscrasias defined as: leukopenia (WBC<3,000 mm3), acute anemia (Hb <9 g/dL), or thrombocytopenia (platelet count <50,000 cells/mm³).
- Subject had severe ventricular dysfunction with left ventricular ejection fraction (LVEF) <20% as measured by resting echocardiogram.
- Subject had renal insufficiency (serum creatinine >3.0 mg/dL (265.5μmol/L)) and/or end stage renal disease requiring chronic dialysis.
Egyéb
- Subject had imaging evidence of intracardiac mass, thrombus or vegetation.
Kiket keres a vizsgálat
- Subject had a degenerated surgical aortic bioprosthetic valve with severe aortic stenosis, severe regurgitation, or a combination of at least moderate stenosis with at least moderate regurgitation per EAPCI-ESC-EACTS standardized criteria.
- Surgical bioprosthesis true inner diameter (true ID) was ≥ 19 mm and ≤ 27 mm and was confirmed by either CT or confirmed by the Valve in Valve Aortic App. Refer to the PCR website https://www.pcronline.com/PCR-Publications/PCR-mobile-apps/Valve-in-Valve-Aortic-app Note: if CT was contraindicated and/or not possible to be obtained, a transesophageal echocardiogram (TEE) will be accepted for sizing.
- Prior to Portico ViV procedure, the patient was deemed at increased risk for surgery to replace the surgical aortic bioprosthetic valve.
- Subject provided written informed consent prior to performing data collection for study specific visits. For patients that are deceased at the time of enrollment, all institutional/local legal and regulatory requirements for consent must be met prior to enrollment and data collection.
- Subject is ≥ 18 years of age or legal age in host country at the time of consent.
- Prior to the Portico ViV index procedure, the subject had New York Heart Association (NYHA) class II, III, or IV.
- Subject had a minimum vessel diameter of 6.0 mm for Portico™ delivery system access or a minimum of 5.0 mm for the FlexNav™ delivery system.
- Subject had the Portico or FlexNav delivery system enter their vasculature
Életkor a regiszterben: 18 év – - · Nem: nők és férfiak · Egészséges önkénteseket nem fogad
Helyszínek (7)
Helyszínek a regiszter sorrendjében. Ha a profilodba mented a városodat, távolság szerint rendeződnek.
| Helyszín | Város | Ország | Helyszín állapota |
|---|---|---|---|
| GenesisCare - St Andrew's Hospital & GenesisCare Leabrook - Satellite Site of GenesisCare - Wesley Hospital | Adelaide | Ausztrália | Ismeretlen állapot |
| GenesisCare - Wesley Hospital | Auchenflower | Ausztrália | Ismeretlen állapot |
| Kerckhoff-Klinik gGmbH | Bad Nauheim | Németország | Ismeretlen állapot |
| Universitätsklinikum Rostock (AöR) | Rostock | Németország | Ismeretlen állapot |
| Rigshospitalet | Copenhagen | Dánia | Ismeretlen állapot |
| St. Bartholomew's Hospital | London | Egyesült Királyság | Ismeretlen állapot |
| Morriston Hospital - ABM University Health Board | Morriston | Egyesült Királyság | Ismeretlen állapot |