Sign in
WithdrawnNo phase

Conventional Instrumentation, Computer Navigation, and Robotic Assistance Techniques in TKA

Key facts

Who runs it
University of California, Los Angeles
Where
Santa Monica, United StatesSee the site
Trial code
Status
Withdrawn
Started
1 Jun 2025
Expected to end
30 Jun 2027
Type of study
Interventional, 3 groupsOne group gets an existing treatment, for comparison.
Treatments tested
  • ROSA Knee System
  • KneeAlign Computer Assisted Navigation System
Record updated
13 August 2024
Why it stopped
Investigator decision

Who can take part

Age
18 years and older
Sex
Women and men
Healthy volunteers
Can take part

The registry criteria, word for word

Show all 12 criteriaShow less

Who can take part

  • Patient is a minimum of 18 years of age
  • Independent of study participation, patient is a candidate for commercially available Persona or Legion knee components implanted in accordance with product labeling
  • Patient has participated in this study-related Informed Consent process
  • Patient is willing and able to provide written Informed Consent by signing and dating the Institutional Review Board (IRB) or Ethics Committee (EC) approved Informed Consent form
  • Patient is willing and able to complete scheduled study procedures and follow-up evaluations

Who cannot take part

  • Patient is currently participating in any other surgical intervention studies or pain management studies
  • Patient has previously received partial or total knee arthroplasty for the ipsilateral knee
  • Patients with active knee joint infections (determined clinically at time of pre-op evaluation)
  • Patient has undergone contralateral unicompartmental knee arthroplasty (UKA) or total knee arthroplasty (TKA) within the last 18 months
  • Hip pathology with significant bone loss (e.g., avascular necrosis of the femoral head with collapse, severe dysplasia of the femoral head or the acetabulum)
  • Hip pathology severely limiting range of motion (e.g., arthrodesis, severe contracture, chronic severe dislocation)
  • Patient is pregnant or considered a member of a protected population (e.g., prisoner, mentally incompetent, etc.)

Where in United States

  • UCLA Santa Monica Medical CenterSanta Monica, United States

About the trial

What the trial wants to find out

Knee osteoarthritis is a debilitating disease that can cause severe knee pain and significant limitations to patients' activities of daily living. Total knee arthroplasty (TKA), also known as knee replacement surgery, is a well-established and successful procedure for treatment of end-stage knee osteoarthritis. Over the years, TKA surgical techniques and implant technology have improved, resulting in better patient outcomes and implant survivorship. Despite continuous improvements being made to this high demand procedure, malalignment of component position is a well-known cause of post-operative complications, including knee pain, component loosening, and failure requiring revision surgery.

Read full original descriptionShow less

Advanced techniques that utilize computer navigation or robotic-arm assistance have been developed in an attempt to avoid malalignment. Both technologies were created with the goal of improving the precision of implant positioning and implant sizing in order to improve lower limb alignment and joint line alignment. The OrthoAlign KneeAlign computer assisted navigation system is a commercially available device that uses gyroscopic limb position sensing technology mounted to intramedullary and extramedullary jigs to measure bone resection cuts in TKA that ultimately dictate implant position. The Zimmer Biomet ROSA Knee System is a commercially available, FDA-approved robotic assistant for performing TKA. It uses pre-operative x-rays to create a three-dimensional image of the patient's knee anatomy, which is used to create a pre-operative template of the implants to be used and provides intra-operative guidance for bone cuts during the TKA. The robotic system also assesses the soft tissue envelope around the knee and can assist with the soft tissue balancing of the knee arthroplasty. Alternatively, it can also be used in an imageless mode where bone cuts are performed based on intra-operative mapping using anatomic landmarks. To date, there have been no prospective studies comparing the implant positioning and patient outcomes directly of the KneeAlign system with the ROSA system and conventional TKA instrumentation techniques.

The 3 groups in the trial

  • ROSAExisting treatment, for comparison

    Subjects randomly assigned to this arm will undergo a primary total knee arthroplasty procedure using the ROSA Knee System.

    Treatment: ROSA Knee System

  • KneeAlignExisting treatment, for comparison

    Subjects randomly assigned to this arm will undergo a primary total knee arthroplasty procedure using the KneeAlign navigation system.

    Treatment: KneeAlign Computer Assisted Navigation System

  • ConventionalNo study treatment, for comparison

    Subjects randomly assigned to this arm will undergo a primary total knee arthroplasty procedure using conventional instrumentation.

Data and sources

Registry record
Listed on ClinicalTrials.gov.How to verify a trial in the registry
Official title
A Prospective, Randomized, Unblinded Trial Comparing Conventional Instrumentation, Hand-Held Accelerometer Based Computer Navigation, and Robotic Assistance Techniques in Total Knee Arthroplasty
Record updated