Tests a portable moving chest X-ray at the bedside in intensive care patients
Tests a portable moving chest X-ray in adults with lung problems in intensive care.
Key facts
- Who runs it
- Brigham and Women's Hospital
- Where
- Boston, United StatesSee the site
- Trial code
- Registry title
- Clinical Utility of Portable Dynamic Chest X Ray (DDR) in the ICU
- Status
- Recruiting
- People taking part
- 230 people, planned
- Started
- 12 Dec 2023
- Expected to end
- Nov 2027
- Type of study
- Interventional
- Treatments tested
- Portable Dynamic Digital Radiography (DDR)
- Record updated
- 29 October 2025
Who can take part
AI summary
From the trial's eligibility criteria. Machine-read from the registry text on this page, so it can be wrong. The registry text below and the trial team decide who can take part.
The trial is looking for adult ICU patients, on a ventilator or not, who are likely to have lung or diaphragm problems. It tests a portable moving chest X-ray at the bedside.
- Age
- 18 years or older
- Sex
- All sexes can join
- Disease stage
- Patients likely to have abnormal diaphragm movement, abnormal lung air content, lung blood flow problems, extra water in the lungs, or swallowing difficulties with a risk of aspiration.
Main reasons for not taking part
- Women with known pregnancy
- Prisoners or institutionalized people
- Patients for whom extra radiation is clinically contraindicated
- Care team does not agree to approaching the patient or their representative
The registry criteria, word for word
Show all 7 criteriaShow less
Who can take part
- Adults (at least 18 years of age) including both intubated/ventilated and non-intubated patients
- Likely to have pathology related to either, abnormal diaphragmatic excursion and lung aeration, pulmonary perfusion, increased lung water content or all the above, as well as for cricopharyngeal dysfunction/swallowing difficulties at risk for aspiration
- The subject or a legally authorized representative has provided written informed consent
Who cannot take part
- Patients where additional radiation is clinically contraindicated
- For women of child-bearing potential, defined as premenopausal women, a pregnancy test will be administered to determine pregnancy status and confirm eligibility for the study. A pregnancy test will NOT be administered to women who are post-menopausal or have documentation of surgical sterilization
- Special populations, including women with known pregnancy, prisoners, or institutionalized individuals
- Care team does not provide assent for approaching patient/surrogate
Where in United States
- Brigham and Women's HospitalBoston, United StatesContact: Gyorgy Frendl, MD, PhDTaking people
About the trial
What the trial wants to find out
Dynamic digital radiography (DDR) is a new advanced version of chest radiography that captures dynamic images at a rate of 15 frames per second. It is coupled with an analytical software that allows it to provide more advanced measures of lung motion, ventilation, and perfusion compared to traditional chest radiography. While implementation of DDR fixed machines are beginning elsewhere in the US, this trial involves the first applications of an FDA-approved portable DDR machine, for use at the bedside in the ICU.
Read full original descriptionShow less
The goal of this clinical trial is to determine the feasibility and safety of portable DDR technology in the ICU, as well as to evaluate the improved clinical diagnostic value of the portable DDR system over current standards of care.
Participants will receive one to three sets of DDR images, which will then be compared to their clinical gold standard exams (such as chest x-rays, CTs, or VQ scans) to assess and improve the precision and accuracy of measurements such as diaphragmatic motion, lung movement, and perfusion.
The group in the trial
- Portable Dynamic Digital Radiography (DDR) + Clinical Gold Standard ImagingTreatment being tested
Dynamic digital radiography (DDR) is a new version of chest radiography from Konica Minolta (KM) that provides more advanced measures of lung motion, ventilation, and perfusion compared to traditional chest radiography. DDR scans are dynamic images that have a rate of 15 frames per second (for 7-20 seconds), acting as a mini-fluorography machine with radiation that is only slightly greater than a traditional chest x-ray. Every patient will receive both a DDR scan and a gold standard scan. Each patient's DDR images will be compared to the golden standard that is completed as part of the patient's routine standard of care. For instance, for many ICU patients this includes traditional chest x-rays, ultrasounds or VQ scans.
Treatment: Portable Dynamic Digital Radiography (DDR)
Questions to ask the study team
- How often do I need to come in, and for how long each time?
- Are travel costs paid?
- Can I keep my own doctor?
- What happens if I want to stop?
Contact the study team: see the registry record → Contacts and Locations
Print a page for my doctorData and sources
- Registry record
- Listed on ClinicalTrials.gov.
- Official title
- Clinical Utility of Portable Dynamic Chest X-Ray (DDR) in the ICU: Clinical Trial to Demonstrate the Feasibility of Deploying DDR Technology in the ICU - A Study to Prove Its Increased Diagnostic Value
- Plain-language title
- Tests a portable moving chest X-ray at the bedside in intensive care patientsGenerated from the registry record. The registry title is the official one.
- AI summary
- From the trial's eligibility criteria. Read by machine on 12 November 2026.
- Record updated
- 29 October 2025