Építés alatt – nem éles oldal
Belépés
BefejeződöttFázis nélkül

FLExAbility Sensor Enabled Substrate Targeted Ablation for the Reduction of VT Study

A legfontosabb adatok

Hol
Ann Arbor, Atlanta, Aurora, Austin, Baltimore, Birmingham, Charleston, Chicago, Fort Lauderdale, Hollywood, Houston, Los Angeles, Minneapolis, Nashville, Philadelphia, Raleigh, Rochester, San Diego, Seattle, Tampa és The Woodlands (Egyesült Államok)Mind a 23 helyszín megnézése

Helyszínek itt: Egyesült Államok

  • University of MichiganAnn Arbor, Egyesült ÁllamokNo longer taking part
  • Emory University HospitalAtlanta, Egyesült ÁllamokNo longer taking part
  • University of Colorado HospitalAurora, Egyesült ÁllamokNo longer taking part
  • Texas Cardiac ArrhythmiaAustin, Egyesült ÁllamokNo longer taking part
  • Johns Hopkins University HospitalBaltimore, Egyesült ÁllamokNo longer taking part
  • Affinity Cardiovascular Specialists, LLCBirmingham, Egyesült ÁllamokNo longer taking part
  • University Hospital - Univ. of Alabama at Birmingham (UAB)Birmingham, Egyesült ÁllamokNo longer taking part
  • Medical University of South CarolinaCharleston, Egyesült ÁllamokNo longer taking part
  • University of ChicagoChicago, Egyesült ÁllamokNo longer taking part
  • Broward General Medical CenterFort Lauderdale, Egyesült ÁllamokNo longer taking part
  • Memorial Regional HospitalHollywood, Egyesült ÁllamokNo longer taking part
  • Texas Heart InstituteHouston, Egyesült ÁllamokNo longer taking part
  • Ronald Reagan UCLA Medical CenterLos Angeles, Egyesült ÁllamokNo longer taking part
  • USC University HospitalLos Angeles, Egyesült ÁllamokNo longer taking part
  • VA Medical Center MinneapolisMinneapolis, Egyesült ÁllamokNo longer taking part
  • Vanderbilt Heart and Vascular InstituteNashville, Egyesült ÁllamokNo longer taking part
  • Hospital of the University of PennsylvaniaPhiladelphia, Egyesült ÁllamokNo longer taking part
  • WakeMed HospitalRaleigh, Egyesült ÁllamokNo longer taking part
  • Mayo ClinicRochester, Egyesült ÁllamokNo longer taking part
  • University of California at San Diego (UCSD) Medical CenterSan Diego, Egyesült ÁllamokNo longer taking part
  • University of WashingtonSeattle, Egyesült ÁllamokNo longer taking part
  • University of South FloridaTampa, Egyesült ÁllamokNo longer taking part
  • Memorial Hermann HospitalThe Woodlands, Egyesült ÁllamokNo longer taking part

A vizsgálat adatai

Ki végzi
Abbott Medical Devices
Azonosító
NCT03490201
A regiszteradat frissítve
2025. január 8.
Eredeti leírás
This clinical investigation is intended to demonstrate the safety and effectiveness of ventricular ablation therapy using the FlexAbility Sensor Enabled Ablation Catheter in patients with drug-refractory monomorphic ventricular tachycardia in whom ventricular tachycardia recurs despite antiarrhythmic drug therapy or when antiarrhythmic drugs are not tolerated or desired.A teljes eredeti leírásKevesebb

FLExAbility Sensor Enabled Substrate Targeted Ablation for the Reduction of Ventricular Tachycardia (LESS-VT) Study

This clinical investigation is intended to demonstrate the safety and effectiveness of ventricular ablation therapy using the FlexAbility Sensor Enabled Ablation Catheter in patients with drug-refractory monomorphic ventricular tachycardia in whom ventricular tachycardia recurs despite antiarrhythmic drug therapy or when antiarrhythmic drugs are not tolerated or desired.

Bevonási feltételek: Structural heart disease (ischemic or non-ischemic) with one of the following:; Confirmed diagnosis via echocardiography and/or cardiac CT/MRI [computed tomography/magnetic resonance imaging], or; Left ventricular ejection fraction (EF) <40% (documented within the last 6 months via echocardiography, or; Arrhythmogenic RV [right ventricular] cardiomyopathy/dysplasia (per 2010 ARVC/D [arrhythmogenic right ventricular cardiomyopathy/dysplasia] Task Force Criteria).27; At least one documented episode of sustained MMVT by either EGM [cardiac electrogram] or ECG [electrocardiogram] in the 6 months prior to enrollment; Implanted with a market released ICD [implantable cardioverter-defibrillator] or CRT-D [cardiac resynchronization therapy-defibrillator] for at least 30 days prior to index ablation procedure; Refractory (i.e. not effective, not tolerated or not desired) to at least one anti-arrhythmic medication (either amiodarone or sotalol) for treatment of MMVT; At least 18 years of age; Informed of the nature of the study, agreed to its provisions and has provided written informed consent as approved by the Institutional Review Board/Ethics Committee (IRB/EC) of the respective clinical study site; Able and willing to comply with all study requirements.

Kizáró feltételek: Currently receiving support, or anticipated to receive support prior to the index ablation procedure, via extracorporeal membrane oxygenation (ECMO); Presence of intracardiac thrombus verified via computer tomography (CT), magnetic resonance imaging (MRI), transesophageal echocardiogram (TEE), or transthoracic echocardiogram (TTE) within 48 hours prior to the index ablation procedure or intra-procedure intracardiac echocardiography (ICE); o For subjects with a history of AF [atrial fibrillation], this verification must be done via TEE or ICE; ST elevation myocardial infarction (MI) within 60 days prior to index ablation procedure; Previous cardiac surgery (e.g. ventriculotomy, atriotomy, coronary artery bypass graft), within 60 days prior to index ablation procedure; Percutaneous coronary intervention (PCI) within 30 days prior to index ablation procedure; Incessant VT (continuous sustained VT that promptly recurs despite repeated intervention for termination over ≥3 hours) necessitating immediate treatment or requiring hemodynamic support prior to the ablation procedure; Contraindication to systemic anticoagulation (i.e. heparin, warfarin, or a direct thrombin inhibitor); Enrolled in an investigational study evaluating another device or drug that would confound the results of this study; History of stroke with modified Rankin scale > 3 (See Appendix C); Unstable angina; Chronic NYHA [New York Heart Association] Class IV heart failure; Active uncontrolled infection; Other anatomic or co morbid conditions or other medical, social, or psychological conditions that, in the investigator's opinion, could limit the patient's ability to participate in the study or to comply with follow up requirements, or impact the scientific soundness of the study results; Have a life expectancy of less than 12 months due to any condition; Ejection fraction < 15%; Thrombocytopenia (defined as platelet count <80,000) or coagulopathy; Implanted with a subcutaneous ICD; Implanted with a ventricular assist device (VAD) (e.g. TandemHeart); Idiopathic VT; VT/VF [ventricular tachycardia/ventricular fibrillation] thought to be from channelopathies; Reversible cause of VT; Severe aortic stenosis or flail mitral valve; Mechanical mitral and aortic valve; Women who are pregnant or nursing.

ClinicalTrials.gov NCT03490201